Temperature‐regulated gold nanoparticle sensors for immune chromatographic rapid test kits with reproducible sensitivity: a study
IET Nanobiotechnology · 2021-05 · 15 (3) · 338-346
DOI: 10.1049/nbt2.12024 ↗Kurz gefasst
Fachartikel in der Zeitschrift IET Nanobiotechnology, online erschienen am 03.03.2021. Verfasst von Prince Manta und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Pharmaceutical Sciences, Shoolini University, Bajhol Solan, Himachal Pradesh, India. Hauptthemen laut MEDLINE: Malaria, Metal Nanoparticles. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Immune‐chromatographic kits are being used since several years in the rapid detection of infectious diseases. It is also called the lateral flow technique, and is used for antigen or antibody detection. There are a series of steps involved in the development of these immune‐chromatographic test kits. Still, the preparation of gold nanoparticles (AuNPs) is an important quality variable for the immune‐chromatographic test kit sensitivity. The immune chromatographic test must be specific in detection for specific antigen and antibody; this implies that the test kit should not show a false result. Secondly, the test kit should be sensitive enough to give a readable result, and the intensity of the test line should increase or decrease with the concentration of an analytic sample. Various factors can influence the performance of a test. Temperature differences in AuNPs preparation can alter the assay kinetics and contribute to assay variability. Other factors such as assay components, manufacturing processes and reagent variation also contribute to assay precision and accuracy. It is important to note that assay reproducibility is the combined effect of individual sources of variability. The authors have synthesized AuNPs by immediately controlling the reaction temperature. Different batches of Malaria rapid test kit were developed and the test kit sensitivity was analysed. It was found that test kits designed with temperature‐controlled AuNPs sensor had reproducible uniformity in terms of batch to batch sensitivity than AuNPs synthesized by conventional Turkevich and Fern process.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- School of Pharmaceutical Sciences, Shoolini University, Bajhol Solan, Himachal Pradesh, India.
- Seloi Healthcare Pvt. Ltd, Goregaon West, Mumbai, India.
ORCID-Profile: Prince Manta, Deepak N Kapoor
Zitieren
APA
Manta, P., Chandra Singh, S., Deep, A., & Kapoor, D. N. (2021). Temperature‐regulated gold nanoparticle sensors for immune chromatographic rapid test kits with reproducible sensitivity: a study. IET Nanobiotechnology, 15(3), 338-346. https://doi.org/10.1049/nbt2.12024
Vancouver
Manta P, Chandra Singh S, Deep A, Kapoor DN. Temperature‐regulated gold nanoparticle sensors for immune chromatographic rapid test kits with reproducible sensitivity: a study. IET Nanobiotechnology. 2021;15(3):338-346. doi:10.1049/nbt2.12024
BibTeX
@article{Manta2021,
author = {Manta, Prince and Chandra Singh, Suresh and Deep, Aman and Kapoor, Deepak N},
title = {Temperature‐regulated gold nanoparticle sensors for immune chromatographic rapid test kits with reproducible sensitivity: a study},
journal = {IET Nanobiotechnology},
year = {2021},
volume = {15},
number = {3},
pages = {338--346},
doi = {10.1049/nbt2.12024}
}
EUVIMED