EUVIMEDEUVIMED entdecken
Crossref

Rapid calibration of bits weights error for high‐resolution successive approximation register ADC

Lu Liu, Daiguo Xu, Shiliu Xu

IET Circuits, Devices & Systems · 2019-05 · 13 (3) · 368-373

DOI: 10.1049/iet-cds.2018.5220 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IET Circuits, Devices & Systems, online erschienen am 15.04.2019. Verfasst von Lu Liu und 2 weiteren Autor:innen. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 20 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study presents the rapid calibration of bits weights error for an 18 bit successive approximation register analogue‐to‐digital converter (ADC). This calibration technique is a new hybrid algorithm. Comparing to the traditional methods, this technique significantly reduces the convergence time and improves the accuracy of bits weights error estimation. There is no wasteful time in the correction process. This proposed approach estimates the bits weights error not only from the digital‐to‐analogue converter capacitor mismatch, inter‐stage gain error, but also the metal insulator metal (MIM), capacitor second‐order voltage coefficient in the ultra‐high‐resolution ADC. The proposed algorithm has been verified with a test 18 bit ADC chip, where measured results show the calibration is able to improve the peak integral nonlinearity (INL), of the ADC from 29 to 1.0 LSB after calibration. Measured results also show the signal‐to‐noise and distortion ratio/spurious‐free dynamic range of the ADC improves from 83/94 to 96/127 dB after calibration. It will be seen that the calibration is achieved in ∼4k cycles, which is more than ×25 faster than previously published algorithm.

Zitieren

APA

Liu, L., Xu, D., & Xu, S. (2019). Rapid calibration of bits weights error for high‐resolution successive approximation register ADC. IET Circuits, Devices & Systems, 13(3), 368-373. https://doi.org/10.1049/iet-cds.2018.5220

Vancouver

Liu L, Xu D, Xu S. Rapid calibration of bits weights error for high‐resolution successive approximation register ADC. IET Circuits, Devices & Systems. 2019;13(3):368-373. doi:10.1049/iet-cds.2018.5220

BibTeX
@article{Liu2019,
  author = {Liu, Lu and Xu, Daiguo and Xu, Shiliu},
  title = {Rapid calibration of bits weights error for high‐resolution successive approximation register ADC},
  journal = {IET Circuits, Devices & Systems},
  year = {2019},
  volume = {13},
  number = {3},
  pages = {368--373},
  doi = {10.1049/iet-cds.2018.5220}
}
Kostenlos starten →