A Thermal‐Dependent Conductivity Coating for Surface Charge and Electric Field Mitigation Under Electrothermal Coupling Field
High Voltage · 2026-08 · 11 (4) · 928-938
DOI: 10.1049/hve2.70189 ↗Kurz gefasst
Fachartikel in der Zeitschrift High Voltage, online erschienen am 27.04.2026. Verfasst von Jianyi Xue und 6 weiteren Autor:innen. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Fundamental Research Funds for the Central Universities, National Natural Science Foundation of China.
Abstract (Originalsprache)
The problem of gas–solid interface charge accumulation is an important reason for distorting the surface electric field and then inducing surface discharge. The temperature gradient distribution formed on the spacer during the operation of a gas‐insulated transmission line (GIL) will aggravate the surface charge accumulation, further threatening the surface insulation performance of the spacer. This study proposes a thermal‐dependent conductivity coating method to regulate the surface charge and electric field distribution on DC GIL spacers under an electrothermal coupling field. Under the temperature gradient, the symmetrically ring‐shaped homocharges around the high‐voltage electrode and the randomly cloud‐shaped bipolar charges are distributed on the uncoated spacer surface. After coating TiO 2 /epoxy mixtures on the spacer surface, the surface charge distribution on the spacer is dramatically homogenised under the thermal gradient, no matter which content of TiO 2 is used. A simulation model for the surface charge and electric field on the spacer with/without TiO 2 /epoxy coating under the electrothermal coupling field is established. The results are well consistent with those of the experiment. When the content of TiO 2 in the coating material increases from 10 wt% to 30 wt%, the maximum electric field strength on the spacer surface gradually decreases and tends to be stable, from 2.7 kV/mm on the uncoated spacer surface to 1.1 kV/mm on the 20‐wt% TiO 2 /epoxy‐coated spacer. We hope that this study can provide guidance for the optimal design of DC GIL spacers under the electrothermal coupling field.
Förderung
- Fundamental Research Funds for the Central Universities
- National Natural Science Foundation of China
Zitieren
APA
Xue, J., Xing, B., Wang, W., Sang, J., Yang, N., Wen, T., & Ding, L. (2026). A Thermal‐Dependent Conductivity Coating for Surface Charge and Electric Field Mitigation Under Electrothermal Coupling Field. High Voltage, 11(4), 928-938. https://doi.org/10.1049/hve2.70189
Vancouver
Xue J, Xing B, Wang W, Sang J, Yang N, Wen T, et al. A Thermal‐Dependent Conductivity Coating for Surface Charge and Electric Field Mitigation Under Electrothermal Coupling Field. High Voltage. 2026;11(4):928-938. doi:10.1049/hve2.70189
BibTeX
@article{Xue2026,
author = {Xue, Jianyi and Xing, Bowen and Wang, Weiming and Sang, Jianzhao and Yang, Ning and Wen, Tao and Ding, Lijian},
title = {A Thermal‐Dependent Conductivity Coating for Surface Charge and Electric Field Mitigation Under Electrothermal Coupling Field},
journal = {High Voltage},
year = {2026},
volume = {11},
number = {4},
pages = {928--938},
doi = {10.1049/hve2.70189}
}