Investigating New Approaches for Optimal Energisations of DC Cables: The Stepwise Energisation Technique

Gian Carlo Montanari, Sukesh Babu Myneni, Grazia Berardi, Marco Albertini, Stefano Franchi Bononi

High Voltage · 2025-12 · 10 (6) · 1371-1379

DOI: 10.1049/hve2.70084 ↗

Kurz gefasst

Fachartikel in der Zeitschrift High Voltage, online erschienen am 17.09.2025. Verfasst von Gian Carlo Montanari und 4 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This paper focuses on the energisation of high voltage DC (HVDC) and medium voltage DC (MVDC) insulation systems, referring mainly to cables for both theoretical development and validation testing. Cable system energisation can be frequent during its lifetime, and it can possibly be affected by partial discharges (PD), because of manufacturing, laying, ageing, interfaces or structural cavities (as butt gaps). A theory‐driven and measurement‐based procedure is presented in this paper, having the purpose to minimise PD inception risk. This procedure is based on stepwise voltage application during cable energisation. The fundamental idea behind the proposed approach stems from considering that the jump voltage is the trigger of PD occurrence. Indeed, the jump voltage, and the consequent electric field variation, directly relates to AC PD inception voltage (PDIV AC ). In addition, the electric field distribution in an insulation system is driven by insulation permittivity (capacitance) during voltage transients, and by conductivity in DC, thus the PDIV AC is generally smaller than DC PD inception voltage (PDIV DC ). Hence, energising a DC cable by an initial step lower than PDIV AC , and then increasing the voltage in steps smaller than PDIV AC , would minimise the risk of PD inception during transients and the relevant degradation rate. However, this does not change, the risk of occurrence (if any) of low‐repetition partial discharges at DC steady state. Effectiveness of the proposed technique is proved by the help of tests performed on cables with artificial surface and internal defects. It is shown that compared with the conventional energisation consisting of rapidly increasing voltage, the stepwise approach can reduce the risk of PD inception and related extrinsic ageing, even for the steady state voltages larger than PDIV DC .

Zitieren

APA

Montanari, G. C., Myneni, S. B., Berardi, G., Albertini, M., & Bononi, S. F. (2025). Investigating New Approaches for Optimal Energisations of DC Cables: The Stepwise Energisation Technique. High Voltage, 10(6), 1371-1379. https://doi.org/10.1049/hve2.70084

Vancouver

Montanari GC, Myneni SB, Berardi G, Albertini M, Bononi SF. Investigating New Approaches for Optimal Energisations of DC Cables: The Stepwise Energisation Technique. High Voltage. 2025;10(6):1371-1379. doi:10.1049/hve2.70084

BibTeX
@article{Montanari2025,
  author = {Montanari, Gian Carlo and Myneni, Sukesh Babu and Berardi, Grazia and Albertini, Marco and Bononi, Stefano Franchi},
  title = {Investigating New Approaches for Optimal Energisations of DC Cables: The Stepwise Energisation Technique},
  journal = {High Voltage},
  year = {2025},
  volume = {10},
  number = {6},
  pages = {1371--1379},
  doi = {10.1049/hve2.70084}
}