The Partial Discharge Characteristics of Inner Air Gap Inside High‐Voltage Cable Termination for High‐Speed Trains
High Voltage · 2025-10 · 10 (5) · 1110-1124
DOI: 10.1049/hve2.70014 ↗Kurz gefasst
Fachartikel in der Zeitschrift High Voltage, online erschienen am 30.06.2025. Verfasst von Dongli Xin und 7 weiteren Autor:innen. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
The air gap at the interface inside the cable terminations for high‐speed trains and the partial discharge caused by it are two important factors affecting the insulating performance. The development of air gap and partial discharge will eventually lead to breakdown faults. To investigate the evolutionary characteristics of the air gap and partial discharge, the simulation models and samples of cable terminations containing defects are constructed in this paper. By analysing the variation law of the electric field and the multidimensional information of partial discharge, the evolution process of the air gap is divided into four well‐characterised stages. Especially in the third stage, the partial discharge extinction voltage is 51.41% lower than that of the defect‐free samples and even lower than the working voltage. The asymmetry of discharge is the most significant factor. The volume of discharge in the third quadrant is significantly higher than that in the first quadrant. This important feature can be applied to the inspection and evaluation of the insulating state of the cable terminations. The partial discharge characteristics of the air gap revealed in this paper are proposed to provide an important theoretical supplement to the study of interface discharges between heterogeneous dielectrics.
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Xin, D., Wu, G., Gao, G., Chen, K., Liu, K., Xie, Y., Lin, M., & Li, B. (2025). The Partial Discharge Characteristics of Inner Air Gap Inside High‐Voltage Cable Termination for High‐Speed Trains. High Voltage, 10(5), 1110-1124. https://doi.org/10.1049/hve2.70014
Vancouver
Xin D, Wu G, Gao G, Chen K, Liu K, Xie Y, et al. The Partial Discharge Characteristics of Inner Air Gap Inside High‐Voltage Cable Termination for High‐Speed Trains. High Voltage. 2025;10(5):1110-1124. doi:10.1049/hve2.70014
BibTeX
@article{Xin2025,
author = {Xin, Dongli and Wu, Guangning and Gao, Guoqiang and Chen, Kui and Liu, Kai and Xie, Yunlong and Lin, Mu and Li, Bo},
title = {The Partial Discharge Characteristics of Inner Air Gap Inside High‐Voltage Cable Termination for High‐Speed Trains},
journal = {High Voltage},
year = {2025},
volume = {10},
number = {5},
pages = {1110--1124},
doi = {10.1049/hve2.70014}
}