Gas production analysis for the buffer layer of high‐voltage cross‐linked polyethylene cables
High Voltage · 2024-10 · 9 (5) · 1149-1158
DOI: 10.1049/hve2.12430 ↗Kurz gefasst
Fachartikel in der Zeitschrift High Voltage, online erschienen am 21.03.2024. Verfasst von Wenqing Zhou und 4 weiteren Autor:innen. Die Arbeit wurde bisher 19-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Guangdong Key Laboratory of Efficient and Clean Energy Utilization, South China University of Technology.
Abstract (Originalsprache)
The cross‐linked polyethylene insulated cables with corrugated aluminium‐sheathed are widely used in urban power systems. Recently, a new type of power cable fault has emerged, primarily due to defects in the buffer layer. However, there is a notable lack of effective evaluation methods for these defects in high‐voltage (HV) cables. Initially, a theoretical analysis of the gas generation mechanism in the cable buffer layer was conducted, identifying distinct gas products at different stages. Subsequently, the diffusion kinetics of gas within the cable was studied, highlighting the importance of gas in determining the state of the buffer layer. The authors then collected and analysed 60 sets of buffer layer gases from two operational 110 kV HV cables using gas chromatography technology. Combining these results with the findings from on‐site inspections, the characteristic gas components and concentration distribution under various defect conditions were summarised. The results found higher concentrations of CH 4 in normal cables and defective cables, while there are higher concentrations of H 2 , CO and CO 2 in defective cables, and the oxygen content decreases. The discoveries made in this research may offer a new approach for assessing the state of the cable buffer layer.
Förderung
- Guangdong Key Laboratory of Efficient and Clean Energy Utilization, South China University of Technology
Zitieren
APA
Zhou, W., Li, L., Cheng, H., Wu, X., & Liu, G. (2024). Gas production analysis for the buffer layer of high‐voltage cross‐linked polyethylene cables. High Voltage, 9(5), 1149-1158. https://doi.org/10.1049/hve2.12430
Vancouver
Zhou W, Li L, Cheng H, Wu X, Liu G. Gas production analysis for the buffer layer of high‐voltage cross‐linked polyethylene cables. High Voltage. 2024;9(5):1149-1158. doi:10.1049/hve2.12430
BibTeX
@article{Zhou2024,
author = {Zhou, Wenqing and Li, Licheng and Cheng, Hao and Wu, Xun and Liu, Gang},
title = {Gas production analysis for the buffer layer of high‐voltage cross‐linked polyethylene cables},
journal = {High Voltage},
year = {2024},
volume = {9},
number = {5},
pages = {1149--1158},
doi = {10.1049/hve2.12430}
}