Reliability and validity of computer vision‐based markerless human pose estimation for measuring hip and knee range of motion
Healthcare Technology Letters · 2025-01 · 12 (1)
DOI: 10.1049/htl2.70002 ↗Kurz gefasst
Fachartikel in der Zeitschrift Healthcare Technology Letters, online erschienen am 31.01.2025. Verfasst von Thomas Hellstén und 4 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Medicine University of Helsinki Helsinki Finland. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Telerehabilitation requires accurate joint range of motion (ROM) measurement methods. The aim of this study was to evaluate the reliability and validity of a computer vision (CV)‐based markerless human pose estimation (HPE) application measuring active hip and knee ROMs. For this study, the joint ROM of 30 healthy young adults (10 females, 20 males) aged 20–33 years (mean: 22.9 years) was measured, and test–retests were assessed for reliability. For validity evaluation, the CV‐based markerless HPE application used in this study was compared with an identical reference picture frame. The intraclass correlation coefficient (ICC) for the CV‐based markerless HPE application was 0.93 for active hip inner rotation, 0.83 for outer rotation, 0.82 for flexion, 0.82 for extension, and 0.74 for knee flexion. Correlations ( r ) of the two measurement methods were 0.99 for hip‐active inner rotation, 0.98 for outer rotation, 0.87 for flexion, 0.85 for extension, and 0.90 for knee flexion. This study highlights the potential of a CV‐based markerless HPE application as a reliable and valid tool for measuring hip and knee joint ROM. It could offer an accessible solution for telerehabilitation, enabling ROM monitoring.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Faculty of Medicine University of Helsinki Helsinki Finland.
- School of Engineering Culture and Wellbeing Arcada University of Applied Sciences Helsinki Finland.
- Department of Internal Medicine and Rehabilitation Division of Rehabilitation Helsinki University Hospital Helsinki Finland.
- Orton Orthopaedic Hospital Helsinki Finland.
- Graduate School and Research Arcada University of Applied Sciences Helsinki Finland.
ORCID-Profile: Thomas Hellstén
Zitieren
APA
Hellstén, T., Arokoski, J., Karlsson, J., Ristolainen, L., & Kettunen, J. (2025). Reliability and validity of computer vision‐based markerless human pose estimation for measuring hip and knee range of motion. Healthcare Technology Letters, 12(1). https://doi.org/10.1049/htl2.70002
Vancouver
Hellstén T, Arokoski J, Karlsson J, Ristolainen L, Kettunen J. Reliability and validity of computer vision‐based markerless human pose estimation for measuring hip and knee range of motion. Healthcare Technology Letters. 2025;12(1). doi:10.1049/htl2.70002
BibTeX
@article{Hellstn2025,
author = {Hellstén, Thomas and Arokoski, Jari and Karlsson, Jonny and Ristolainen, Leena and Kettunen, Jyrki},
title = {Reliability and validity of computer vision‐based markerless human pose estimation for measuring hip and knee range of motion},
journal = {Healthcare Technology Letters},
year = {2025},
volume = {12},
number = {1},
doi = {10.1049/htl2.70002}
}
EUVIMED