Fachartikel in der Zeitschrift Healthcare Technology Letters, online erschienen am 15.01.2025. Verfasst von Zahra Asadi und 4 weiteren Autor:innen. Beteiligte Einrichtung: Gina Cody School of Engineering and Computer Science Concordia University Montreal Quebec Canada. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Global disparities in neurosurgical care necessitate innovations addressing affordability and accuracy, particularly for critical procedures like ventriculostomy. This intervention, vital for managing life‐threatening intracranial pressure increases, is associated with catheter misplacement rates exceeding 30% when using a freehand technique. Such misplacements hold severe consequences including haemorrhage, infection, prolonged hospital stays, and even morbidity and mortality. To address this issue, a novel, stand‐alone mobile‐based augmented reality system (iSurgARy) aimed at significantly improving ventriculostomy accuracy, particularly in resource‐limited settings such as those in low‐ and middle‐income countries is presented. iSurgARy uses landmark based registration by taking advantage of light detection and ranging to allow for accurate surgical guidance. To evaluate iSurgARy, a two‐phase user study is conducted. Initially, the usability and learnability is assessed with novice participants using the system usability scale (SUS), incorporating their feedback to refine the application. In the second phase, human‐computer interaction and clinical domain experts are engaged to evaluate this application, measuring root mean square error, SUS and NASA task load index metrics to assess accuracy usability, and cognitive workload, respectively.

Schlagwörter

Stichwörter der Autor:innen

augmented realitybrainhealth careimage fusionman‐machine systemsmobile computingsmart phonessurgeryvirtual reality

Autor:innen und Institutionen

  • Gina Cody School of Engineering and Computer Science Concordia University Montreal Quebec Canada.
  • Departments of Neurology and Neurosurgery, Montreal Neurological Institute and Hospital McGill University Montreal Quebec Canada.

Zitieren

APA

Asadi, Z., Castillo, J. P., Asadi, M., Sinclair, D. S., & Kersten-Oertel, M. (2025). iSurgARy: A mobile augmented reality solution for ventriculostomy in resource‐limited settings. Healthcare Technology Letters, 12(1). https://doi.org/10.1049/htl2.12118

Vancouver

Asadi Z, Castillo JP, Asadi M, Sinclair DS, Kersten-Oertel M. iSurgARy: A mobile augmented reality solution for ventriculostomy in resource‐limited settings. Healthcare Technology Letters. 2025;12(1). doi:10.1049/htl2.12118

BibTeX
@article{Asadi2025,
  author = {Asadi, Zahra and Castillo, Joshua Pardillo and Asadi, Mehrdad and Sinclair, David S and Kersten-Oertel, Marta},
  title = {iSurgARy: A mobile augmented reality solution for ventriculostomy in resource‐limited settings},
  journal = {Healthcare Technology Letters},
  year = {2025},
  volume = {12},
  number = {1},
  doi = {10.1049/htl2.12118}
}
Kostenlos starten →