Deep regression 2D‐3D ultrasound registration for liver motion correction in focal tumour thermal ablation
Healthcare Technology Letters · 2025-01 · 12 (1)
DOI: 10.1049/htl2.12117 ↗Kurz gefasst
Fachartikel in der Zeitschrift Healthcare Technology Letters, online erschienen am 17.02.2025. Verfasst von Shuwei Xing und 5 weiteren Autor:innen. Beteiligte Einrichtung: Robarts Research Institute Western University London Canada. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Natural Sciences and Engineering Research Council of Canada, Ontario Institute for Cancer Research.
Abstract (Originalsprache)
Liver tumour ablation procedures require accurate placement of the needle applicator at the tumour centroid. The lower‐cost and real‐time nature of ultrasound (US) has advantages over computed tomography for applicator guidance, however, in some patients, liver tumours may be occult on US and tumour mimics can make lesion identification challenging. Image registration techniques can aid in interpreting anatomical details and identifying tumours, but their clinical application has been hindered by the tradeoff between alignment accuracy and runtime performance, particularly when compensating for liver motion due to patient breathing or movement. Therefore, we propose a 2D–3D US registration approach to enable intra‐procedural alignment that mitigates errors caused by liver motion. Specifically, our approach can correlate imbalanced 2D and 3D US image features and use continuous 6D rotation representations to enhance the model's training stability. The dataset was divided into 2388, 196, and 193 image pairs for training, validation and testing, respectively. Our approach achieved a mean Euclidean distance error of and a mean geodesic angular error of , with a runtime of per 2D–3D US image pair. These results demonstrate that our approach can achieve accurate alignment and clinically acceptable runtime, indicating potential for clinical translation.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Robarts Research Institute Western University London Canada.
- School of Biomedical Engineering Western University London Canada.
- Department of Medical Imaging Western University London Canada.
- Lawson Health Research Institute London Canada.
- Department of Medical Biophysics Western University London Canada.
ORCID-Profile: Shuwei Xing, Derek W Cool
Förderung
- Natural Sciences and Engineering Research Council of Canada
- Ontario Institute for Cancer Research
Zitieren
APA
Xing, S., Cool, D. W., Tessier, D., Chen, E. C. S., Peters, T. M., & Fenster, A. (2025). Deep regression 2D‐3D ultrasound registration for liver motion correction in focal tumour thermal ablation. Healthcare Technology Letters, 12(1). https://doi.org/10.1049/htl2.12117
Vancouver
Xing S, Cool DW, Tessier D, Chen ECS, Peters TM, Fenster A. Deep regression 2D‐3D ultrasound registration for liver motion correction in focal tumour thermal ablation. Healthcare Technology Letters. 2025;12(1). doi:10.1049/htl2.12117
BibTeX
@article{Xing2025,
author = {Xing, Shuwei and Cool, Derek W and Tessier, David and Chen, Elvis C S and Peters, Terry M and Fenster, Aaron},
title = {Deep regression 2D‐3D ultrasound registration for liver motion correction in focal tumour thermal ablation},
journal = {Healthcare Technology Letters},
year = {2025},
volume = {12},
number = {1},
doi = {10.1049/htl2.12117}
}
EUVIMED