Optimal Control Strategy for Frequency Support of Energy Storage Doubly‐Fed Condenser Considering Frequency Trajectory Characteristics of Power Systems
IET Generation, Transmission & Distribution · 2026-01 · 20 (1)
DOI: 10.1049/gtd2.70377 ↗Kurz gefasst
Fachartikel in der Zeitschrift IET Generation, Transmission & Distribution, online erschienen am 22.07.2026. Verfasst von Shuqiang Zhao und 3 weiteren Autor:innen. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: National Key Research and Development Program of China.
Abstract (Originalsprache)
With the large‐scale integration of renewable energy, the rotational inertia of power systems has significantly decreased, leading to prominent frequency stability issues. The Energy Storage Doubly‐Fed Condenser (ESDFC) is regarded as an effective means to provide fast frequency support owing to its considerable rotor kinetic energy reserve enabled by wide slip operation capability. However, existing approaches mainly emulate synchronous generator inertia or track ideal frequency trajectories through additional active power control loops, which often involve complex controller structures, suffer from control discontinuities during mode switching, and lack overall optimisation of frequency dynamics under constraints. To address these issues, this paper proposes a frequency trajectory control strategy for ESDFC based on rotor speed control. A dual‐objective optimised power‐frequency transfer function is first developed to simultaneously constrain the initial rate of change of frequency (RoCoF) and minimise frequency nadir deviation. Secondly, combined with the ESDFC rotor motion equation and the power‐frequency transfer function, an integrated rotor speed control command is derived, enabling seamless connection between steady‐state constant‐speed operation, transient inertia support, and autonomous speed recovery without mode switching. Furthermore, an adaptive parameter optimisation method is designed to dynamically adjust control parameters according to initial disturbance characteristics and speed constraints, ensuring safe and efficient operation under various conditions. Simulation results on the IEEE 39‐bus system demonstrate that the proposed strategy effectively suppresses the frequency deviation and RoCoF at critical buses while achieving faster and smoother frequency recovery, thereby enhancing frequency stability in high‐renewable power systems.
Förderung
- National Key Research and Development Program of China
Zitieren
APA
Zhao, S., Zhang, S., Jiang, Y., & Wang, H. (2026). Optimal Control Strategy for Frequency Support of Energy Storage Doubly‐Fed Condenser Considering Frequency Trajectory Characteristics of Power Systems. IET Generation, Transmission & Distribution, 20(1). https://doi.org/10.1049/gtd2.70377
Vancouver
Zhao S, Zhang S, Jiang Y, Wang H. Optimal Control Strategy for Frequency Support of Energy Storage Doubly‐Fed Condenser Considering Frequency Trajectory Characteristics of Power Systems. IET Generation, Transmission & Distribution. 2026;20(1). doi:10.1049/gtd2.70377
BibTeX
@article{Zhao2026,
author = {Zhao, Shuqiang and Zhang, Sitong and Jiang, Yihang and Wang, Hui},
title = {Optimal Control Strategy for Frequency Support of Energy Storage Doubly‐Fed Condenser Considering Frequency Trajectory Characteristics of Power Systems},
journal = {IET Generation, Transmission & Distribution},
year = {2026},
volume = {20},
number = {1},
doi = {10.1049/gtd2.70377}
}
EUVIMED