Recovery Control Strategies and Overcurrent Suppression for Bipolar Hybrid Cascaded MTDC Systems Under DC Faults
IET Generation, Transmission & Distribution · 2026-01 · 20 (1)
DOI: 10.1049/gtd2.70328 ↗Kurz gefasst
Fachartikel in der Zeitschrift IET Generation, Transmission & Distribution, online erschienen am 21.05.2026. Verfasst von Muhammad Asim Mond und 2 weiteren Autor:innen. Die Arbeit nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Key Research and Development Program of China.
Abstract (Originalsprache)
Bipolar hybrid cascaded multi‐terminal high‐voltage direct current (MTDC) systems feature the power density of LCCs, combined with the flexible control capabilities of the MMCs, which are suitable for long‐distance bulk power transmission and can integrate renewable energy sources on a large scale, including the Baihetan‐Jiangsu hybrid cascaded MTDC project proposed in China. The co‐existence of these converter technologies, however, leads to complicated DC fault behaviour that is very challenging to manage and recover from after faults. This paper will provide a detailed discussion of DC faults in the bipolar hybrid cascaded MTDC systems, the faults in the line‐commutated converter (LCC) section, the hybrid LCC‐MMC interface, and the modular multilevel converter (MMC) section. The electrical characteristics of DC faults are determined with the help of electromagnetic transient simulations, which consider the voltage collapse, fault current propagation, and converter stress. After being determined to have common electrical signatures and dynamic behaviours, a new classification scheme is proposed, which classifies faults that share common characteristics, dynamic responses, and system‐level responses. The control actions needed to alleviate the effects of DC faults, such as firing‐angle control of LCCs, blocking and deblocking MMCs, and coordinated AC and DC circuit breaker operation, are also another focus of this paper. It pays special attention to the effective DC fault current suppression, voltage stabilisation, and minimisation of stress on LCC and MMC converters. Moreover, the recovery strategy is worked out, and three recovery cases are investigated for each of the major categories of faults. In these cases, different control sequences, converter re‐energisation schemes, and breaker operation to stabilise the system and resume normal operation were involved. The effectiveness of the proposed fault classification, control actions, and recovery strategies is confirmed on the background of a PSCAD/EMTDC model of the Baihetan‐Jiangsu hybrid cascaded MTDC system.
Förderung
- National Key Research and Development Program of China
Zitieren
APA
Mond, M. A., Li, Z., & Mei, W. (2026). Recovery Control Strategies and Overcurrent Suppression for Bipolar Hybrid Cascaded MTDC Systems Under DC Faults. IET Generation, Transmission & Distribution, 20(1). https://doi.org/10.1049/gtd2.70328
Vancouver
Mond MA, Li Z, Mei W. Recovery Control Strategies and Overcurrent Suppression for Bipolar Hybrid Cascaded MTDC Systems Under DC Faults. IET Generation, Transmission & Distribution. 2026;20(1). doi:10.1049/gtd2.70328
BibTeX
@article{Mond2026,
author = {Mond, Muhammad Asim and Li, Zhou and Mei, Wenwen},
title = {Recovery Control Strategies and Overcurrent Suppression for Bipolar Hybrid Cascaded MTDC Systems Under DC Faults},
journal = {IET Generation, Transmission & Distribution},
year = {2026},
volume = {20},
number = {1},
doi = {10.1049/gtd2.70328}
}