EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

A Hybrid Control Strategy to Boost Robustness and Harmonic Suppression Ability of Grid‐Tied Inverter in Weak Grid with Background Harmonics

Damin Zhang, Jinping Huang, BinBin Chen, Jiongqiong Cao, Yuanzhong Zhang

IET Generation, Transmission & Distribution · 2025-01 · 19 (1)

DOI: 10.1049/gtd2.70143 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IET Generation, Transmission & Distribution, online erschienen am 03.09.2025. Verfasst von Damin Zhang und 4 weiteren Autor:innen. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Natural Science Foundation of Fujian Province, National Natural Science Foundation of China, Natural Science Foundation of Xiamen Municipality.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The operational robustness of grid‐tied inverters is critically challenged under weak grid conditions characterized by wide variations in grid impedance, while background harmonics in grid voltage induced by nonlinear loads severely degrade current quality. To address these dual challenges, this paper proposes a hybrid control strategy integrating an outer‐loop repetitive control (RC) with an inner‐loop proportional‐phase lag compensation (PPLC) architecture. The proposed approach first establishes an equivalent current loop model and employs the PPLC strategy to stabilize system operation across a broad range of grid impedance fluctuations. Subsequently, an outer‐loop RC scheme is systematically designed to enhance harmonic suppression. Key innovations include the implementation of a zero‐phase‐shift low‐pass filter as the inner model parameter in the outer loop, combined with a compensator comprising a second‐order low‐pass filter, a phase‐lead network, and an adaptive gain coefficient. Comprehensive simulations and experimental validations conducted on a semi‐physical platform demonstrate that the hybrid strategy effectively maintains system stability under broad grid impedance variations (up to 18mH) and severe background harmonic distortion. The controlled grid current exhibits total harmonic distortion below 2%, satisfying IEEE 1547 standards while achieving superior robustness and enhanced harmonic attenuation. This dual‐loop architecture provides a systematic solution for grid‐tied inverters operating in challenging weak grid environments with nonlinear load disturbances.

Förderung

  • Natural Science Foundation of Fujian Province
  • National Natural Science Foundation of China
  • Natural Science Foundation of Xiamen Municipality

Zitieren

APA

Zhang, D., Huang, J., Chen, B., Cao, J., & Zhang, Y. (2025). A Hybrid Control Strategy to Boost Robustness and Harmonic Suppression Ability of Grid‐Tied Inverter in Weak Grid with Background Harmonics. IET Generation, Transmission & Distribution, 19(1). https://doi.org/10.1049/gtd2.70143

Vancouver

Zhang D, Huang J, Chen B, Cao J, Zhang Y. A Hybrid Control Strategy to Boost Robustness and Harmonic Suppression Ability of Grid‐Tied Inverter in Weak Grid with Background Harmonics. IET Generation, Transmission & Distribution. 2025;19(1). doi:10.1049/gtd2.70143

BibTeX
@article{Zhang2025,
  author = {Zhang, Damin and Huang, Jinping and Chen, BinBin and Cao, Jiongqiong and Zhang, Yuanzhong},
  title = {A Hybrid Control Strategy to Boost Robustness and Harmonic Suppression Ability of Grid‐Tied Inverter in Weak Grid with Background Harmonics},
  journal = {IET Generation, Transmission & Distribution},
  year = {2025},
  volume = {19},
  number = {1},
  doi = {10.1049/gtd2.70143}
}
Kostenlos starten →