EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Deployment of a full‐size converter utilised hydropower plant to enhance inter‐area oscillation damping

Daniel Fank, Herwig Renner

IET Generation, Transmission & Distribution · 2024-05 · 18 (10) · 1992-2005

DOI: 10.1049/gtd2.13165 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IET Generation, Transmission & Distribution, 2024-05. Verfasst von Daniel Fank und 1 weiteren Autor:innen. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 57 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Due to the increasing share of inverter‐based renewable energy sources and the increased retrofitting of conventional hydropower plants with power electronics, novel possibilities arise for providing damping power in case of occurring inter‐area oscillations in power systems. This paper presents a complete model of a variable‐speed hydropower plant (VSHP) in a single‐machine infinite bus system. The demonstrated analytical model is applied for small‐signal stability analysis that contains all relevant converter dynamics and is verified by an additional non‐linear time‐domain simulation. The damping controller approach located in the full‐size converter (FSC) consists of the classical power system stabilizer with additional phase compensation, to which an appropriate wide‐area input signal is fed via a phasor measurement unit device. Subsequently, the FSC‐VSHP with additional damping algorithm is examined with respect to the significantly higher damping performance with regard to inter‐area modes in a three‐machine model.

Zitieren

APA

Fank, D., & Renner, H. (2024). Deployment of a full‐size converter utilised hydropower plant to enhance inter‐area oscillation damping. IET Generation, Transmission & Distribution, 18(10), 1992-2005. https://doi.org/10.1049/gtd2.13165

Vancouver

Fank D, Renner H. Deployment of a full‐size converter utilised hydropower plant to enhance inter‐area oscillation damping. IET Generation, Transmission & Distribution. 2024;18(10):1992-2005. doi:10.1049/gtd2.13165

BibTeX
@article{Fank2024,
  author = {Fank, Daniel and Renner, Herwig},
  title = {Deployment of a full‐size converter utilised hydropower plant to enhance inter‐area oscillation damping},
  journal = {IET Generation, Transmission & Distribution},
  year = {2024},
  volume = {18},
  number = {10},
  pages = {1992--2005},
  doi = {10.1049/gtd2.13165}
}
Kostenlos starten →