EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Attentive Dual‐Domain Modelling for Error‐Resilient Net Load Forecasting in Intermittent Renewable Power Systems

Bizhi Wu, Zhiyi Li

IET Energy Systems Integration · 2026-01 · 8 (1)

DOI: 10.1049/esi2.70037 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IET Energy Systems Integration, online erschienen am 10.03.2026. Verfasst von Bizhi Wu und 1 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 54 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: State Key Laboratory of Marine Environmental Science.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Accurate long‐sequence net load forecasting is essential for reliable grid operation and renewable integration, yet it remains challenging under quasi‐periodicity, sharp weather‐driven variability and long‐range error accumulation. We propose HarmoNet, an end‐to‐end dual‐domain architecture for long‐horizon deterministic and interval forecasting. HarmoNet (i) encodes coupled low/high‐frequency representations with multi‐scale temporal signals, (ii) integrates local pattern modelling and global dependency learning via a hybrid convolutional‐transformer block and (iii) aggregates horizon‐wide representations to mitigate drift in long‐range prediction. Uncertainty is estimated with quantile regression (10%–50%–90%). We evaluate HarmoNet on four‐year hourly net‐load datasets from Belgium, Bulgaria and Italy (2016–2019) derived from the Open Power System Data platform, using eight exogenous meteorological covariates, over horizons of 96/192/336/720 h. Relative to the strongest baseline per dataset‐horizon setting, HarmoNet reduces MAE by 14.2% on average (up to 22.5% on Italy at 720 h) and achieves average reductions of 28.4% in the Winkler score and 13.0% in pinball loss. Under deployment‐oriented stress tests spanning high‐volatility, peak‐spike and steep‐ramp windows, HarmoNet attains the best deterministic accuracy in 27/36 windows and the best probabilistic performance in 32/36 windows, indicating robust and deployment‐friendly long‐horizon forecasting.

Förderung

  • State Key Laboratory of Marine Environmental Science

Zitieren

APA

Wu, B., & Li, Z. (2026). Attentive Dual‐Domain Modelling for Error‐Resilient Net Load Forecasting in Intermittent Renewable Power Systems. IET Energy Systems Integration, 8(1). https://doi.org/10.1049/esi2.70037

Vancouver

Wu B, Li Z. Attentive Dual‐Domain Modelling for Error‐Resilient Net Load Forecasting in Intermittent Renewable Power Systems. IET Energy Systems Integration. 2026;8(1). doi:10.1049/esi2.70037

BibTeX
@article{Wu2026,
  author = {Wu, Bizhi and Li, Zhiyi},
  title = {Attentive Dual‐Domain Modelling for Error‐Resilient Net Load Forecasting in Intermittent Renewable Power Systems},
  journal = {IET Energy Systems Integration},
  year = {2026},
  volume = {8},
  number = {1},
  doi = {10.1049/esi2.70037}
}
Kostenlos starten →