EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Sensorless Standstill Diagnosis of Rotating Diode Open‐Circuit Faults in WFSSG via Current‐Vector Modulus

Luhuan Shi, Ruihua Li, Junlei Ma, Zan Zhang, Weizhou Li, Yaohui Li, Biao Wang, Baozhong Qu

IET Electric Power Applications · 2026-01 · 20 (1)

DOI: 10.1049/elp2.70197 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IET Electric Power Applications, online erschienen am 22.06.2026. Verfasst von Luhuan Shi und 7 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Henan Provincial Science and Technology Research Project.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Open‐circuit (OC) faults in rotating diode rectifiers (RDRs) pose a severe threat to the operational safety and reliability of wound‐field synchronous starter/generator (WFSSG) systems. Although existing position‐sensorless diagnostic frameworks based on the rotor current vector modulus (CVM) are theoretically applicable to both rotating and stationary conditions, prior research has primarily established characteristic mechanisms, analytical relationships and threshold criteria specifically for rotating operation. Under standstill conditions, the DC components of the three‐phase rotor currents do not contribute to stator electrical signals due to the absence of time‐varying magnetic fields. Consequently, the DC components of the rotor current no longer contribute to the formation of stator‐side signatures, rendering the CVM mathematical expressions and fault criteria established under rotating conditions no longer applicable. To address theoretical gaps under standstill conditions, this paper analyses fundamental differences in feature formation between rotating and stationary states using electromagnetic induction laws. An analytical standstill CVM model is derived within the CVM framework, and characteristic indicators with identification thresholds are established for static detection. Experimental results validate the derived standstill CVM analytical model and the proposed diagnostic indices, demonstrating that the method can accurately and robustly identify dual‐diode open‐circuit faults in the rotating diode rectifier under standstill conditions.

Förderung

  • Henan Provincial Science and Technology Research Project

Zitieren

APA

Shi, L., Li, R., Ma, J., Zhang, Z., Li, W., Li, Y., Wang, B., & Qu, B. (2026). Sensorless Standstill Diagnosis of Rotating Diode Open‐Circuit Faults in WFSSG via Current‐Vector Modulus. IET Electric Power Applications, 20(1). https://doi.org/10.1049/elp2.70197

Vancouver

Shi L, Li R, Ma J, Zhang Z, Li W, Li Y, et al. Sensorless Standstill Diagnosis of Rotating Diode Open‐Circuit Faults in WFSSG via Current‐Vector Modulus. IET Electric Power Applications. 2026;20(1). doi:10.1049/elp2.70197

BibTeX
@article{Shi2026,
  author = {Shi, Luhuan and Li, Ruihua and Ma, Junlei and Zhang, Zan and Li, Weizhou and Li, Yaohui and Wang, Biao and Qu, Baozhong},
  title = {Sensorless Standstill Diagnosis of Rotating Diode Open‐Circuit Faults in WFSSG via Current‐Vector Modulus},
  journal = {IET Electric Power Applications},
  year = {2026},
  volume = {20},
  number = {1},
  doi = {10.1049/elp2.70197}
}
Infokarte | EUVIMED