EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Transient stability of grid following inverters: The impacts of damping and fault ride‐through

Qi Zhang, Yunjie Gu, Dong Liu, Chenxu Wang, Kehu Yang, Zhe Chen

Energy Internet · 2024-11 · 1 (2) · 150-165

DOI: 10.1049/ein2.12014 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Energy Internet, online erschienen am 14.08.2024. Verfasst von Qi Zhang und 5 weiteren Autor:innen. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: China Scholarship Council.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The interaction of grid following inverters with a weak grid raises risks of transient instability. The effects of damping and fault‐ride through (FRT) make the transient dynamics more complicated. To investigate the impact of FRT on the transient stability of converters, this paper first employs the switch system theory to construct a mathematical model for the synchronous mechanism of inverters. Secondly, the method of semi‐algebraic system real root classification is comprehensively used to analyse the existence of equilibrium points (EPs) and provide necessary and sufficient conditions for their existence. Finally, based on the theory of differential geometry, a method for computing the stability domain of converters is proposed. Compared with traditional methods, the results obtained from this approach are precise and non‐conservative. The study in this paper indicates that the equivalent damping effect from the proportional control in a phase‐locked loop significantly enlarges the stability region, whereas the active current injection shrinks the stability region. The reactive current droop characteristic also has impacts on the stability region, especially with active current injection. The switchover between the droop mode and constant current mode requires extra precaution in the calculation of the EPs and critical fault clearing time.

Förderung

  • China Scholarship Council

Zitieren

APA

Zhang, Q., Gu, Y., Liu, D., Wang, C., Yang, K., & Chen, Z. (2024). Transient stability of grid following inverters: The impacts of damping and fault ride‐through. Energy Internet, 1(2), 150-165. https://doi.org/10.1049/ein2.12014

Vancouver

Zhang Q, Gu Y, Liu D, Wang C, Yang K, Chen Z. Transient stability of grid following inverters: The impacts of damping and fault ride‐through. Energy Internet. 2024;1(2):150-165. doi:10.1049/ein2.12014

BibTeX
@article{Zhang2024,
  author = {Zhang, Qi and Gu, Yunjie and Liu, Dong and Wang, Chenxu and Yang, Kehu and Chen, Zhe},
  title = {Transient stability of grid following inverters: The impacts of damping and fault ride‐through},
  journal = {Energy Internet},
  year = {2024},
  volume = {1},
  number = {2},
  pages = {150--165},
  doi = {10.1049/ein2.12014}
}