Establishment of urinary hydrogen peroxide as an early indicator for AKI monitoring and its electrochemical detection
Dalton Transactions · 2026
DOI: 10.1039/d6dt01959e ↗Kurz gefasst
Fachartikel in der Zeitschrift Dalton Transactions, 2026. Verfasst von Wenhao Bai und 6 weiteren Autor:innen. Beteiligte Einrichtung: College of Chemistry and Materials Science, Jiangsu Key Laboratory of Bio-functional Materials, Jiangsu Collaborative Innovation Centre of Biomedical…. Hauptthemen laut MEDLINE: Hydrogen Peroxide, Acute Kidney Injury, Electrochemical Techniques. Die Arbeit nennt 21 Literaturangaben. Gefördert von: Priority Academic Program Development of Jiangsu Higher Education Institutions.
Abstract (Originalsprache)
A CuO/ZnPc-Cu modified screen-printed sensor enables non-invasive electrochemical detection of urinary H 2 O 2 , achieving early acute kidney injury (AKI) diagnosis 3 h prior to traditional clinical indicators.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- College of Chemistry and Materials Science, Jiangsu Key Laboratory of Bio-functional Materials, Jiangsu Collaborative Innovation Centre of Biomedical Functional Materials, Nanjing Normal University, Nanjing, 210023, Chi…
- College of Life Sciences, Huaiyin Normal University, Huaiyin, 223300, China.
- State Key Laboratory of Flexible Electronics (LoFE) & Jiangsu Key Laboratory of Smart Biomaterials and Theranostic Technology, Institute of Advanced Materials (IAM), Nanjing University of Posts and Telecommunications, N…
- Department of Urology, Nanjing Drum Tower Hospital, the Affiliated Hospital of Nanjing University Medical School, Institute of Urology, Nanjing University, Nanjing, 210008, China. dengyongming@njglyy.com.
Förderung
- Priority Academic Program Development of Jiangsu Higher Education Institutions
Zitieren
APA
Bai, W., Huang, C., Pan, J., Liu, H., Wang, Y., Zhou, L., & Deng, Y. (2026). Establishment of urinary hydrogen peroxide as an early indicator for AKI monitoring and its electrochemical detection. Dalton Transactions. https://doi.org/10.1039/d6dt01959e
Vancouver
Bai W, Huang C, Pan J, Liu H, Wang Y, Zhou L, et al. Establishment of urinary hydrogen peroxide as an early indicator for AKI monitoring and its electrochemical detection. Dalton Transactions. 2026. doi:10.1039/d6dt01959e
BibTeX
@article{Bai2026,
author = {Bai, Wenhao and Huang, Cheng and Pan, JunHao and Liu, Haowen and Wang, Yicheng and Zhou, Lin and Deng, Yongming},
title = {Establishment of urinary hydrogen peroxide as an early indicator for AKI monitoring and its electrochemical detection},
journal = {Dalton Transactions},
year = {2026},
doi = {10.1039/d6dt01959e}
}
EUVIMED