EUVIMEDEUVIMED entdecken
Crossref

A donor–π-acceptor fluorescent probe for hydrogen peroxide monitoring reveals oxidative imbalance and mitochondrial damage caused by Cd/Hg exposure

Jiangkun Tan, Congzheng Zhu, Liangwei Zhang, Yunqing Wang, Xiaoyan Wang, Ping Liu, Li Zhang, Qian Yang, Jinmao You, Lingxin Chen

The Analyst · 2026 · 151 (15) · 4443-4452

DOI: 10.1039/d6an00412a ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Analyst, 2026. Verfasst von Jiangkun Tan und 9 weiteren Autor:innen. Beteiligte Einrichtung: Shandong Key Laboratory of Coastal Zone Environmental Processes and Ecological Security, Coastal Zone Ecological Environment Monitoring Technology an…. Hauptthemen laut MEDLINE: Hydrogen Peroxide, Fluorescent Dyes, Mitochondria. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 54 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Taishan Scholar Project of Shandong Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

We developed a high-performance fluorescent probe, TQ-H 2 O 2 , to visualize H 2 O 2 dynamics and reveal how Cd 2+ /Hg 2+ cause oxidative stress, mitochondrial dysfunction, and cell damage.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Hydrogen PeroxideFluorescent DyesMitochondriaOxidative StressFluorescent Chemosensor CompoundsLimit of DetectionHep G2 CellsZebrafishSpectrometry, FluorescenceHumansAnimals

Substanzen

Hydrogen PeroxideFluorescent DyesFluorescent Chemosensor Compounds

Autor:innen und Institutionen

  • Shandong Key Laboratory of Coastal Zone Environmental Processes and Ecological Security, Coastal Zone Ecological Environment Monitoring Technology and Equipment Shandong Engineering Research Center, Yantai Institute of…
  • University of Chinese Academy of Sciences, Beijing 100049, China.
  • School of Pharmacy, Shandong Medical and Pharmaceutical University, Yantai 264003, China.
  • College of Chemistry and Chemical Engineering, Institute for Advanced Study, Shaoxing University, Shaoxing 312000, China.
  • Laboratory for Marine Biology and Biotechnology, Qingdao Marine Science and Technology Center, Qingdao 266237, China.

Förderung

  • National Natural Science Foundation of China
  • Taishan Scholar Project of Shandong Province

Zitieren

APA

Tan, J., Zhu, C., Zhang, L., Wang, Y., Wang, X., Liu, P., Zhang, L., Yang, Q., You, J., & Chen, L. (2026). A donor–π-acceptor fluorescent probe for hydrogen peroxide monitoring reveals oxidative imbalance and mitochondrial damage caused by Cd/Hg exposure. The Analyst, 151(15), 4443-4452. https://doi.org/10.1039/d6an00412a

Vancouver

Tan J, Zhu C, Zhang L, Wang Y, Wang X, Liu P, et al. A donor–π-acceptor fluorescent probe for hydrogen peroxide monitoring reveals oxidative imbalance and mitochondrial damage caused by Cd/Hg exposure. The Analyst. 2026;151(15):4443-4452. doi:10.1039/d6an00412a

BibTeX
@article{Tan2026,
  author = {Tan, Jiangkun and Zhu, Congzheng and Zhang, Liangwei and Wang, Yunqing and Wang, Xiaoyan and Liu, Ping and Zhang, Li and Yang, Qian and You, Jinmao and Chen, Lingxin},
  title = {A donor–π-acceptor fluorescent probe for hydrogen peroxide monitoring reveals oxidative imbalance and mitochondrial damage caused by Cd/Hg exposure},
  journal = {The Analyst},
  year = {2026},
  volume = {151},
  number = {15},
  pages = {4443--4452},
  doi = {10.1039/d6an00412a}
}
Kostenlos starten →