EUVIMEDEUVIMED entdecken
Crossref

A ratiometric fluorescent sensor based on carbon dots encapsulated in ZIF-8 for visual discrimination and detection of tetracycline and chlortetracycline

Jin Wang, Baojie Liu, Jixing Liang, Hongguo Hao, Yaoyao Wang, Yunwu Li, Suna Wang

Nanoscale · 2026 · 18 (12) · 6605-6617

DOI: 10.1039/d5nr04604a ↗

Kurz gefasst

Fachartikel in der Zeitschrift Nanoscale, 2026. Verfasst von Jin Wang und 6 weiteren Autor:innen. Beteiligte Einrichtung: Shandong Provincial Key Laboratory of Chemical Energy Storage and Novel Cell Technology, School of Chemistry and Chemical Engineering, Liaocheng Univ…. Hauptthemen laut MEDLINE: Carbon Quantum Dots, Chlortetracycline, Tetracycline, Anti-Bacterial Agents. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 65 Literaturangaben. Gefördert von: Natural Science Foundation of Shandong Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

CDs@ZIF-8 enables ratiometric fluorescence detection of TC/CTC and demonstrates low detection limits and excellent visual detection performance. A portable colorimetric sensing platform integrated with a ratiometric logic gate was developed.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Carbon Quantum DotsChlortetracyclineTetracyclineAnti-Bacterial AgentsImidazolesZeolitesFluorescent DyesLimit of DetectionSpectrometry, FluorescenceFluorescent Chemosensor CompoundsColorimetryAnimalsCarbon

Substanzen

ChlortetracyclineTetracyclineAnti-Bacterial AgentsImidazolesFluorescent Chemosensor CompoundsZeolitesCarbonFluorescent Dyes

Autor:innen und Institutionen

  • Shandong Provincial Key Laboratory of Chemical Energy Storage and Novel Cell Technology, School of Chemistry and Chemical Engineering, Liaocheng University, Liaocheng, 252059, P. R. China. liyunwu@lcu.edu.cn.

Förderung

  • Natural Science Foundation of Shandong Province

Zitieren

APA

Wang, J., Liu, B., Liang, J., Hao, H., Wang, Y., Li, Y., & Wang, S. (2026). A ratiometric fluorescent sensor based on carbon dots encapsulated in ZIF-8 for visual discrimination and detection of tetracycline and chlortetracycline. Nanoscale, 18(12), 6605-6617. https://doi.org/10.1039/d5nr04604a

Vancouver

Wang J, Liu B, Liang J, Hao H, Wang Y, Li Y, et al. A ratiometric fluorescent sensor based on carbon dots encapsulated in ZIF-8 for visual discrimination and detection of tetracycline and chlortetracycline. Nanoscale. 2026;18(12):6605-6617. doi:10.1039/d5nr04604a

BibTeX
@article{Wang2026,
  author = {Wang, Jin and Liu, Baojie and Liang, Jixing and Hao, Hongguo and Wang, Yaoyao and Li, Yunwu and Wang, Suna},
  title = {A ratiometric fluorescent sensor based on carbon dots encapsulated in ZIF-8 for visual discrimination and detection of tetracycline and chlortetracycline},
  journal = {Nanoscale},
  year = {2026},
  volume = {18},
  number = {12},
  pages = {6605--6617},
  doi = {10.1039/d5nr04604a}
}
Kostenlos starten →