SERS-based lateral flow immunoassay utilising plasmonic nanoparticle clusters for ultra-sensitive detection of salivary cortisol
Nanoscale · 2025 · 17 (34) · 19656-19665
DOI: 10.1039/d5nr02062j ↗Kurz gefasst
Fachartikel in der Zeitschrift Nanoscale, 2025. Verfasst von Hyun-Kyung Oh und 13 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical Engineering and Electronics, University of Liverpool, UK. S.Maher@liverpool.ac.uk. Hauptthemen laut MEDLINE: Hydrocortisone, Saliva, Metal Nanoparticles, Spectrum Analysis, Raman. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 55 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 3.0). Gefördert von: University of Liverpool, National Tsing Hua University, Engineering and Physical Sciences Research Council.
Abstract (Originalsprache)
We report the first SERS-based LFIA for salivary cortisol, achieving 0.014 pg mL −1 sensitivity—650× better than conventional LFIAs— via size-controlled Au clusters and dual-line Raman mapping, with strong correlation to UPLC-MS/MS.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Electrical Engineering and Electronics, University of Liverpool, UK. S.Maher@liverpool.ac.uk.
- Department of Engineering and System Science, National Tsing Hua University, Taiwan.
- Department of Endocrinology, Alder Hey Children's Hospital NHS Foundation Trust, Liverpool, UK.
- Sensor Research Unit, Department of Chemistry, Faculty of Science, Chulalongkorn University, Thailand.
- Centre for Metabolomics Research, Department of Biochemistry, Cell and Systems Biology, Institute of Systems, Molecular and Integrative Biology, University of Liverpool, UK.
- Department of Biomedical Sciences and Engineering, National Central University, Taoyuan 320317, Taiwan.
Förderung
- University of Liverpool
- National Tsing Hua University
- Engineering and Physical Sciences Research Council
Zitieren
APA
Oh, H. K., Akbali, B., Sham, T. T., Haworth-Duff, A., Blair, J. C., Smith, B. L., Sricharoen, N., Lima, C., Chen, T. Y., Huang, C. H., Wongravee, K., Kim, M. G., Goodacre, R., & Maher, S. (2025). SERS-based lateral flow immunoassay utilising plasmonic nanoparticle clusters for ultra-sensitive detection of salivary cortisol. Nanoscale, 17(34), 19656-19665. https://doi.org/10.1039/d5nr02062j
Vancouver
Oh HK, Akbali B, Sham TT, Haworth-Duff A, Blair JC, Smith BL, et al. SERS-based lateral flow immunoassay utilising plasmonic nanoparticle clusters for ultra-sensitive detection of salivary cortisol. Nanoscale. 2025;17(34):19656-19665. doi:10.1039/d5nr02062j
BibTeX
@article{Oh2025,
author = {Oh, Hyun-Kyung and Akbali, Baris and Sham, Tung-Ting and Haworth-Duff, Adam and Blair, Joanne C and Smith, Barry L and Sricharoen, Nontawat and Lima, Cassio and Chen, Tsan-Yao and Huang, Chen-Han and Wongravee, Kanet and Kim, Min-Gon and Goodacre, Royston and Maher, Simon},
title = {SERS-based lateral flow immunoassay utilising plasmonic nanoparticle clusters for ultra-sensitive detection of salivary cortisol},
journal = {Nanoscale},
year = {2025},
volume = {17},
number = {34},
pages = {19656--19665},
doi = {10.1039/d5nr02062j}
}
EUVIMED