EUVIMEDEUVIMED entdecken
Crossref

An adaptive weighted polynomial baseline correction method for electrochemical aptamer-based sensors

Zhijian Wen, Yasmin Liu, Emeka J Itumoh, Janet Stacey, James M Curran, Onyekachi Raymond

The Analyst · 2026

DOI: 10.1039/d5an01347j ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Analyst, 2026. Verfasst von Zhijian Wen und 5 weiteren Autor:innen. Beteiligte Einrichtung: New Zealand Institute of Public Health and Forensic Science (PHF Science), Forensic Research and Development, PO Box 50348, Porirua 5022, New Zealand…. Hauptthemen laut MEDLINE: Aptamers, Nucleotide, Biosensing Techniques, Electrochemical Techniques. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 31 Literaturangaben. Gefördert von: Ministry of Business, Innovation and Employment.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

An adaptive polynomial baseline correction method developed for square-wave voltammetry (SWV) data to identify non-informative regions, apply weighted polynomial fitting, and select the optimal order for accurate baseline estimation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Aptamers, NucleotideBiosensing TechniquesElectrochemical TechniquesCocaineHumansAlgorithms

Substanzen

Aptamers, NucleotideCocaine

Autor:innen und Institutionen

  • New Zealand Institute of Public Health and Forensic Science (PHF Science), Forensic Research and Development, PO Box 50348, Porirua 5022, New Zealand. onyekachi.raymond@phfscience.nz.
  • Department of Statistics, University of Auckland, Private Bag 92019, Auckland 1142, New Zealand.

Förderung

  • Ministry of Business, Innovation and Employment

Zitieren

APA

Wen, Z., Liu, Y., Itumoh, E. J., Stacey, J., Curran, J. M., & Raymond, O. (2026). An adaptive weighted polynomial baseline correction method for electrochemical aptamer-based sensors. The Analyst. https://doi.org/10.1039/d5an01347j

Vancouver

Wen Z, Liu Y, Itumoh EJ, Stacey J, Curran JM, Raymond O. An adaptive weighted polynomial baseline correction method for electrochemical aptamer-based sensors. The Analyst. 2026. doi:10.1039/d5an01347j

BibTeX
@article{Wen2026,
  author = {Wen, Zhijian and Liu, Yasmin and Itumoh, Emeka J and Stacey, Janet and Curran, James M and Raymond, Onyekachi},
  title = {An adaptive weighted polynomial baseline correction method for electrochemical aptamer-based sensors},
  journal = {The Analyst},
  year = {2026},
  doi = {10.1039/d5an01347j}
}
Kostenlos starten →