EUVIMEDEUVIMED entdecken
Open Access · CC BY 3.0

Hypochlorite-activated analyte-replacement fluorogenic probes for minute-level fast detection of acute kidney injury

Tingfei Xie, Jiahui Chen, Xiaolu Sui, Yanzi Zhang, Jiqiang Liu, Jinxin Zhang, Xuechuan Hong, Daoyong Jiang, Pengfei Zhang, Jihong Chen

The Analyst · 2025

DOI: 10.1039/d5an00859j ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Analyst, 2025. Verfasst von Tingfei Xie und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Nephrology, The People's Hospital of Baoan Shenzhen, The Second Affiliated Hospital of Shenzhen University, Shenzhen Hospital of Guangd…. Hauptthemen laut MEDLINE: Hypochlorous Acid, Acute Kidney Injury, Fluorescent Dyes. Die Arbeit nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 3.0). Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Guangxi Province, Basic and Applied Basic Research Foundation of Guangdong Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A sample-to-answer approach for minute-level fast detection acute kidney injury has been developed by using an analyte replacement near-infrared fluorogenic probe, which does not require complex equipment and well-trained personnel and enhance AKI diagnostics by enabling rapid, accurate decisions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Hypochlorous AcidAcute Kidney InjuryFluorescent DyesAnimalsHumansMice

Substanzen

Hypochlorous AcidFluorescent Dyes

Autor:innen und Institutionen

  • Department of Nephrology, The People's Hospital of Baoan Shenzhen, The Second Affiliated Hospital of Shenzhen University, Shenzhen Hospital of Guangdong Provincial People's Hospital, Shenzhen School of Clinical Medicine…
  • Guangdong Key Laboratory of Nanomedicine, Chinese Academy of Sciences-Hong Kong Joint Lab for Biomaterials, Chinese Academy of Sciences Key Laboratory of Biomedical Imaging Science and System, Shenzhen Key Laboratory of…
  • Department of Cardiology, Zhongnan Hospital of Wuhan University, School of Pharmaceutical Sciences, Wuhan University, Wuhan, 430071, China.
  • School of Chemistry and Life Sciences, Guilin Normal University, Guilin, Guangxi 541199, PR China.

Förderung

  • National Natural Science Foundation of China
  • Natural Science Foundation of Guangxi Province
  • Basic and Applied Basic Research Foundation of Guangdong Province
  • National Key Research and Development Program of China
  • Shenzhen Science and Technology Innovation Program

Zitieren

APA

Xie, T., Chen, J., Sui, X., Zhang, Y., Liu, J., Zhang, J., Hong, X., Jiang, D., Zhang, P., & Chen, J. (2025). Hypochlorite-activated analyte-replacement fluorogenic probes for minute-level fast detection of acute kidney injury. The Analyst. https://doi.org/10.1039/d5an00859j

Vancouver

Xie T, Chen J, Sui X, Zhang Y, Liu J, Zhang J, et al. Hypochlorite-activated analyte-replacement fluorogenic probes for minute-level fast detection of acute kidney injury. The Analyst. 2025. doi:10.1039/d5an00859j

BibTeX
@article{Xie2025,
  author = {Xie, Tingfei and Chen, Jiahui and Sui, Xiaolu and Zhang, Yanzi and Liu, Jiqiang and Zhang, Jinxin and Hong, Xuechuan and Jiang, Daoyong and Zhang, Pengfei and Chen, Jihong},
  title = {Hypochlorite-activated analyte-replacement fluorogenic probes for minute-level fast detection of acute kidney injury},
  journal = {The Analyst},
  year = {2025},
  doi = {10.1039/d5an00859j}
}
Kostenlos starten →