EUVIMEDEUVIMED entdecken
Crossref

Ultrasensitive electroanalytical sensing platform using aptamer-conjugated V 2 CT x MXene for the detection of the HER-2 biomarker

Reema Rawat, Sonam Singh, Souradeep Roy, Samarika Dubey, Tapas Goswami, Ashish Mathur, James McLaughlin

Nanoscale · 2025 · 17 (17) · 10761-10770

DOI: 10.1039/d4nr04503c ↗

Kurz gefasst

Fachartikel in der Zeitschrift Nanoscale, 2025. Verfasst von Reema Rawat und 6 weiteren Autor:innen. Beteiligte Einrichtung: Health Technology Cluster, School of Health Sciences and Technology, UPES, Dehradun, India. ashish.mathur@ddn.upes.ac.in. Hauptthemen laut MEDLINE: Aptamers, Nucleotide, Erb-b2 Receptor Tyrosine Kinases, Electrochemical Techniques, Biosensing Techniques. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 43 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A cost-effective, ultrasensitive electrochemical aptasensor using V 2 CT x MXene is developed for real-time, point-of-care HER-2 breast cancer detection, offering high sensitivity, selectivity, and suitability for resource-limited settings.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Aptamers, NucleotideErb-b2 Receptor Tyrosine KinasesElectrochemical TechniquesBiosensing TechniquesBiomarkers, TumorHumansLimit of DetectionFemaleBreast NeoplasmsNitritesTransition Elements

Substanzen

Aptamers, NucleotideErb-b2 Receptor Tyrosine KinasesBiomarkers, TumorNitritesTransition ElementsERBB2 protein, humanMXene

Autor:innen und Institutionen

  • Health Technology Cluster, School of Health Sciences and Technology, UPES, Dehradun, India. ashish.mathur@ddn.upes.ac.in.
  • Department of Chemistry, School of Advanced Engineering, UPES, Dehradun, India.
  • The Tons Bridge School, Nanda ki Chowki, Premnagar, Dehradun, India.
  • Centre for Interdisciplinary Research and Innovation (CIDRI), UPES, Dehradun, India.
  • School of Engineering, Ulster University, Belfast, UK.

Zitieren

APA

Rawat, R., Singh, S., Roy, S., Dubey, S., Goswami, T., Mathur, A., & McLaughlin, J. (2025). Ultrasensitive electroanalytical sensing platform using aptamer-conjugated V 2 CT x MXene for the detection of the HER-2 biomarker. Nanoscale, 17(17), 10761-10770. https://doi.org/10.1039/d4nr04503c

Vancouver

Rawat R, Singh S, Roy S, Dubey S, Goswami T, Mathur A, et al. Ultrasensitive electroanalytical sensing platform using aptamer-conjugated V 2 CT x MXene for the detection of the HER-2 biomarker. Nanoscale. 2025;17(17):10761-10770. doi:10.1039/d4nr04503c

BibTeX
@article{Rawat2025,
  author = {Rawat, Reema and Singh, Sonam and Roy, Souradeep and Dubey, Samarika and Goswami, Tapas and Mathur, Ashish and McLaughlin, James},
  title = {Ultrasensitive electroanalytical sensing platform using aptamer-conjugated V 2 CT x MXene for the detection of the HER-2 biomarker},
  journal = {Nanoscale},
  year = {2025},
  volume = {17},
  number = {17},
  pages = {10761--10770},
  doi = {10.1039/d4nr04503c}
}
Kostenlos starten →