A biocompatible Ni( ii ) complex as an amyloid sensor for human PrP 106–126 fibrillar aggregates
Chemical Communications · 2025
DOI: 10.1039/d4cc04335a ↗Kurz gefasst
Fachartikel in der Zeitschrift Chemical Communications, 2025. Verfasst von Rajat Saini und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Indian Institute of Technology, Roorkee 247667, India. kaushik.ghosh@cy.iitr.ac.in. Hauptthemen laut MEDLINE: Nickel, Coordination Complexes, Fluorescent Dyes, Biocompatible Materials. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 24 Literaturangaben. Gefördert von: Council of Scientific and Industrial Research, India, Department of Science and Technology, Ministry of Science and Technology, India, Ministry of Education, India.
Abstract (Originalsprache)
A novel probe (KRS-1) for detecting human PrP 106–126 aggregation was synthesized. Through PL measurements with KRS-1 and ThT, the stages of PrP 106–126 aggregation are shown. KRS-1 was employed to detect PrP 106–126 aggregates in neuronal HT-22 cells.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Chemistry, Indian Institute of Technology, Roorkee 247667, India. kaushik.ghosh@cy.iitr.ac.in.
- Department of Biosciences and Bioengineering, Indian Institute of Technology, Roorkee 247667, India. kg@bt.iitr.ac.in.
- Department of Chemistry, National Institute of Technology Manipur, Langol-795004, India.
Förderung
- Council of Scientific and Industrial Research, India
- Department of Science and Technology, Ministry of Science and Technology, India
- Ministry of Education, India
Zitieren
APA
Saini, R., Chauhan, R., Singh, S., Saini, S., Navale, G. R., Panwar, A., Kukreti, P., Ahmed, I., Roy, P., & Ghosh, K. (2025). A biocompatible Ni( ii ) complex as an amyloid sensor for human PrP 106–126 fibrillar aggregates. Chemical Communications. https://doi.org/10.1039/d4cc04335a
Vancouver
Saini R, Chauhan R, Singh S, Saini S, Navale GR, Panwar A, et al. A biocompatible Ni( ii ) complex as an amyloid sensor for human PrP 106–126 fibrillar aggregates. Chemical Communications. 2025. doi:10.1039/d4cc04335a
BibTeX
@article{Saini2025,
author = {Saini, Rajat and Chauhan, Rahul and Singh, Sain and Saini, Saakshi and Navale, Govinda R and Panwar, Abhishek and Kukreti, Prashant and Ahmed, Imtiaz and Roy, Partha and Ghosh, Kaushik},
title = {A biocompatible Ni( ii ) complex as an amyloid sensor for human PrP 106–126 fibrillar aggregates},
journal = {Chemical Communications},
year = {2025},
doi = {10.1039/d4cc04335a}
}
EUVIMED