EUVIMEDEUVIMED entdecken
Crossref

Certification and long-term stability monitoring of low-content folic acid and 5-methyltetrahydrofolate in human plasma certified reference material by isotope dilution ultra-high performance liquid chromatography/tandem mass spectrometry

Seok-Won Hyung iD, Joonhee Lee, Byungjoo Kim iD, Sunyoung Lee, Song-Yee Baek, JeeSoo Han

Analytical Methods · 2024

DOI: 10.1039/d4ay00997e ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Methods, 2024. Verfasst von Seok-Won Hyung und 5 weiteren Autor:innen. Beteiligte Einrichtung: Division of Chemical and Material Metrology, Korea Research Institute of Standards and Science, Yuseong, Daejeon 34113, Republic of Korea. swhyung@kr…. Hauptthemen laut MEDLINE: Tetrahydrofolates, Tandem Mass Spectrometry, Folic Acid. Die Arbeit nennt 32 Literaturangaben. Gefördert von: Korea Research Institute of Standards and Science.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A reliable measurement of blood folate levels is necessary to prevent diseases. This human plasma certified reference material can be used to establish the analytical method for low-content folic acid and 5-methyltetrahydrofolate.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TetrahydrofolatesTandem Mass SpectrometryFolic AcidHumansChromatography, High Pressure LiquidReference StandardsDrug Stability

Substanzen

Tetrahydrofolates5-methyltetrahydrofolateFolic Acid

Autor:innen und Institutionen

  • Division of Chemical and Material Metrology, Korea Research Institute of Standards and Science, Yuseong, Daejeon 34113, Republic of Korea. swhyung@kriss.re.kr.

ORCID-Profile: Seok-Won Hyung, Byungjoo Kim

Förderung

  • Korea Research Institute of Standards and Science

Zitieren

APA

Hyung, S. W., Lee, J., Kim, B., Lee, S., Baek, S. Y., & Han, J. (2024). Certification and long-term stability monitoring of low-content folic acid and 5-methyltetrahydrofolate in human plasma certified reference material by isotope dilution ultra-high performance liquid chromatography/tandem mass spectrometry. Analytical Methods. https://doi.org/10.1039/d4ay00997e

Vancouver

Hyung SW, Lee J, Kim B, Lee S, Baek SY, Han J. Certification and long-term stability monitoring of low-content folic acid and 5-methyltetrahydrofolate in human plasma certified reference material by isotope dilution ultra-high performance liquid chromatography/tandem mass spectrometry. Analytical Methods. 2024. doi:10.1039/d4ay00997e

BibTeX
@article{Hyung2024,
  author = {Hyung, Seok-Won and Lee, Joonhee and Kim, Byungjoo and Lee, Sunyoung and Baek, Song-Yee and Han, JeeSoo},
  title = {Certification and long-term stability monitoring of low-content folic acid and 5-methyltetrahydrofolate in human plasma certified reference material by isotope dilution ultra-high performance liquid chromatography/tandem mass spectrometry},
  journal = {Analytical Methods},
  year = {2024},
  doi = {10.1039/d4ay00997e}
}
Kostenlos starten →