Development of in vitro microfluidic models to study endothelial responses to pulsatility with different mechanical circulatory support devices

Xueying Wang, Lixue Liang, Guruprasad A Giridharan, Palaniappan Sethu, Yanxia Wang, Kai-Rong Qin, Peng Qu, Yu Wang

The Analyst · 2024

DOI: 10.1039/d4an00507d ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Analyst, 2024. Verfasst von Xueying Wang und 7 weiteren Autor:innen. Beteiligte Einrichtung: School of Optoelectronic Engineering and Instrumentation Science, Dalian University of Technology, Dalian 116024, Liaoning Province, P. R. China. Hauptthemen laut MEDLINE: Heart-Assist Devices, Pulsatile Flow. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 65 Literaturangaben. Gefördert von: NHLBI NIH HHS, Natural Science Foundation of Shandong Province, Foundation for the National Institutes of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

CPD can replace CFVAD with pulsatile working modes to a certain extent to treat non-severe HF. The proposed in vitro microfluidic models provided scientific basis for selecting different mechanical circulatory support devices.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heart-Assist DevicesPulsatile FlowHumansEndothelial CellsReactive Oxygen SpeciesLab-On-A-Chip DevicesStress, MechanicalHuman Umbilical Vein Endothelial CellsCounterpulsationNitric Oxide

Substanzen

Reactive Oxygen SpeciesNitric Oxide

Autor:innen und Institutionen

  • School of Optoelectronic Engineering and Instrumentation Science, Dalian University of Technology, Dalian 116024, Liaoning Province, P. R. China.
  • School of Mechanical Engineering, Dalian University of Technology, Dalian 116024, Liaoning Province, P. R. China.
  • Department of Bioengineering, University of Louisville, Louisville, KY 40292, USA.
  • Department of Biomedical Engineering, School of Engineering, University of Alabama at Birmingham, Birmingham, AL 35294, USA.
  • School of Rehabilitation Medicine, Shandong Second Medical University, Weifang 261053, Shandong Province, P. R. China.
  • School of Biomedical Engineering, Faculty of Medicine, Dalian University of Technology, Dalian 116024, Liaoning Province, P. R. China. qupeng@dlut.edu.cn.

Förderung

  • NHLBI NIH HHS
  • Natural Science Foundation of Shandong Province
  • Foundation for the National Institutes of Health
  • National Natural Science Foundation of China

Zitieren

APA

Wang, X., Liang, L., Giridharan, G. A., Sethu, P., Wang, Y., Qin, K. R., Qu, P., & Wang, Y. (2024). Development of in vitro microfluidic models to study endothelial responses to pulsatility with different mechanical circulatory support devices. The Analyst. https://doi.org/10.1039/d4an00507d

Vancouver

Wang X, Liang L, Giridharan GA, Sethu P, Wang Y, Qin KR, et al. Development of in vitro microfluidic models to study endothelial responses to pulsatility with different mechanical circulatory support devices. The Analyst. 2024. doi:10.1039/d4an00507d

BibTeX
@article{Wang2024,
  author = {Wang, Xueying and Liang, Lixue and Giridharan, Guruprasad A and Sethu, Palaniappan and Wang, Yanxia and Qin, Kai-Rong and Qu, Peng and Wang, Yu},
  title = {Development of in vitro microfluidic models to study endothelial responses to pulsatility with different mechanical circulatory support devices},
  journal = {The Analyst},