EUVIMEDEUVIMED entdecken
Crossref

A mesothelin microsensor based on an embedded thionine electronic medium within an imprinted polymer on an acupuncture needle electrode

Yi Zhang, Xue Kong, Hai-Yang Guo, Jing Wang, Zheng-Zhi Yin

The Analyst · 2024

DOI: 10.1039/d4an00490f ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Analyst, 2024. Verfasst von Yi Zhang und 4 weiteren Autor:innen. Beteiligte Einrichtung: College of Chemical Engineering, Zhejiang University of Technology, Hangzhou 310014, China. Jingw1986@zjut.edu.cn. Hauptthemen laut MEDLINE: Phenothiazines, Electrodes, Limit of Detection, Biosensing Techniques. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 35 Literaturangaben. Gefördert von: Science and Technology Program of Zhejiang Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

An electrochemical microsensor of mesothelin was prepared based on surface imprinted nano-interface coordinated embedded thionine, and it was constructed via a green route of electrosynthesis and self-assembly.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PhenothiazinesElectrodesLimit of DetectionBiosensing TechniquesElectrochemical TechniquesMesothelinHumansMolecularly Imprinted PolymersNeedlesGoldGPI-Linked Proteins

Substanzen

PhenothiazinesthionineMesothelinMolecularly Imprinted PolymersGoldMSLN protein, humanGPI-Linked Proteins

Autor:innen und Institutionen

  • College of Chemical Engineering, Zhejiang University of Technology, Hangzhou 310014, China. Jingw1986@zjut.edu.cn.
  • College of Biological, Chemical Sciences and Engineering, Jiaxing University, Jiaxing 314001, China. yinzhengzhi@zjxu.edu.cn.
  • Jiaxing Key Laboratory of Molecular Recognition and Sensing, College of Biological, Chemical Sciences and Engineering, Jiaxing University, Jiaxing 314001. China.

Förderung

  • Science and Technology Program of Zhejiang Province

Zitieren

APA

Zhang, Y., Kong, X., Guo, H. Y., Wang, J., & Yin, Z. Z. (2024). A mesothelin microsensor based on an embedded thionine electronic medium within an imprinted polymer on an acupuncture needle electrode. The Analyst. https://doi.org/10.1039/d4an00490f

Vancouver

Zhang Y, Kong X, Guo HY, Wang J, Yin ZZ. A mesothelin microsensor based on an embedded thionine electronic medium within an imprinted polymer on an acupuncture needle electrode. The Analyst. 2024. doi:10.1039/d4an00490f

BibTeX
@article{Zhang2024,
  author = {Zhang, Yi and Kong, Xue and Guo, Hai-Yang and Wang, Jing and Yin, Zheng-Zhi},
  title = {A mesothelin microsensor based on an embedded thionine electronic medium within an imprinted polymer on an acupuncture needle electrode},
  journal = {The Analyst},
  year = {2024},
  doi = {10.1039/d4an00490f}
}
Kostenlos starten →