EUVIMEDEUVIMED entdecken
Crossref

Development of enzyme–inorganic hybrid nanoflower-modified electrodes and a smartphone-controlled electrochemical analyzer for point-of-care testing of salivary amylase in saliva

Cong Liu, Xia Gong, Xiao Yang, Zipei Yu, Weihao Li, Guangyi Liao, Chuanquan Lin, Lelun Jiang, Changqing Yi

Nanoscale · 2024

DOI: 10.1039/d3nr04388f ↗

Kurz gefasst

Fachartikel in der Zeitschrift Nanoscale, 2024. Verfasst von Cong Liu und 8 weiteren Autor:innen. Beteiligte Einrichtung: Guangdong Provincial Engineering and Technology Center of Advanced and Portable Medical Devices, School of Biomedical Engineering, Sun Yat-Sen Univer…. Hauptthemen laut MEDLINE: Saliva, Salivary alpha-Amylases. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 46 Literaturangaben. Gefördert von: Guangzhou Municipal Science and Technology Project.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study reports a POCT system for sAA quantitation with clinically acceptable accuracy in any setting. Preliminary clinical studies using this system reveal the great potential of sAA as an early warning indicator of abnormal glucose metabolism.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SalivaSalivary alpha-AmylasesHumansSmartphoneGlucosePoint-of-Care TestingElectrodesObesity

Substanzen

GlucoseSalivary alpha-Amylases

Autor:innen und Institutionen

  • Guangdong Provincial Engineering and Technology Center of Advanced and Portable Medical Devices, School of Biomedical Engineering, Sun Yat-Sen University, Guangzhou, 510275, PR China. yichq@mail.sysu.edu.cn.
  • Science and Technology Innovation Center, Guangzhou University of Chinese Medicine, Guangzhou, 510405, PR China. chuanquanlin@gzucm.edu.cn.

Förderung

  • Guangzhou Municipal Science and Technology Project

Zitieren

APA

Liu, C., Gong, X., Yang, X., Yu, Z., Li, W., Liao, G., Lin, C., Jiang, L., & Yi, C. (2024). Development of enzyme–inorganic hybrid nanoflower-modified electrodes and a smartphone-controlled electrochemical analyzer for point-of-care testing of salivary amylase in saliva. Nanoscale. https://doi.org/10.1039/d3nr04388f

Vancouver

Liu C, Gong X, Yang X, Yu Z, Li W, Liao G, et al. Development of enzyme–inorganic hybrid nanoflower-modified electrodes and a smartphone-controlled electrochemical analyzer for point-of-care testing of salivary amylase in saliva. Nanoscale. 2024. doi:10.1039/d3nr04388f

BibTeX
@article{Liu2024,
  author = {Liu, Cong and Gong, Xia and Yang, Xiao and Yu, Zipei and Li, Weihao and Liao, Guangyi and Lin, Chuanquan and Jiang, Lelun and Yi, Changqing},
  title = {Development of enzyme–inorganic hybrid nanoflower-modified electrodes and a smartphone-controlled electrochemical analyzer for point-of-care testing of salivary amylase in saliva},
  journal = {Nanoscale},
  year = {2024},
  doi = {10.1039/d3nr04388f}
}
Kostenlos starten →