Comparison between dynamic versus static models and real-time monitoring of neuronal dysfunction in an amyloid-β induced neuronal toxic model on a chip platform
Lab on a Chip · 2024
DOI: 10.1039/d3lc00507k ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Lab on a Chip, 2024. Verfasst von Chu-Chun Liang und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, No. 101, Section 2, Kuang-Fu Road, Hsinchu 300044, Ta…. Hauptthemen laut MEDLINE: Neural Stem Cells, Neurodegenerative Diseases. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 3.0). Gefördert von: Ministry of Science and Technology, Taiwan, National Tsing Hua University, Chang Gung University.
Abstract (Originalsprache)
A 3D neural spheroid-based system with an interstitial level of flow for simulating the brain microenvironment toward a dynamic amyloid-β induced neuronal toxic model was established. A real-time impedance recording was used to monitor the neural network formation and disconnection.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, No. 101, Section 2, Kuang-Fu Road, Hsinchu 300044, Taiwan. iclee@mx.nthu.edu.tw.
- Department of Chemical and Biomolecular Engineering, University of Maryland, College Park, Maryland, 20742, USA.
ORCID-Profile: Chu-Chun Liang, Po-Yen Chen, I-Chi Lee
Förderung
- Ministry of Science and Technology, Taiwan
- National Tsing Hua University
- Chang Gung University
- University of Maryland
Zitieren
APA
Liang, C. C., Chen, P. Y., Liu, N. C., & Lee, I. C. (2024). Comparison between dynamic versus static models and real-time monitoring of neuronal dysfunction in an amyloid-β induced neuronal toxic model on a chip platform. Lab on a Chip. https://doi.org/10.1039/d3lc00507k
Vancouver
Liang CC, Chen PY, Liu NC, Lee IC. Comparison between dynamic versus static models and real-time monitoring of neuronal dysfunction in an amyloid-β induced neuronal toxic model on a chip platform. Lab on a Chip. 2024. doi:10.1039/d3lc00507k
BibTeX
@article{Liang2024,
author = {Liang, Chu-Chun and Chen, Po-Yen and Liu, Nien-Che and Lee, I-Chi},
title = {Comparison between dynamic versus static models and real-time monitoring of neuronal dysfunction in an amyloid-β induced neuronal toxic model on a chip platform},
journal = {Lab on a Chip},
year = {2024},
doi = {10.1039/d3lc00507k}
}
EUVIMED