EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY-NC 3.0

Comparison between dynamic versus static models and real-time monitoring of neuronal dysfunction in an amyloid-β induced neuronal toxic model on a chip platform

Chu-Chun Liang iD, Po-Yen Chen iD, Nien-Che Liu, I-Chi Lee iD

Lab on a Chip · 2024

DOI: 10.1039/d3lc00507k ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Lab on a Chip, 2024. Verfasst von Chu-Chun Liang und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, No. 101, Section 2, Kuang-Fu Road, Hsinchu 300044, Ta…. Hauptthemen laut MEDLINE: Neural Stem Cells, Neurodegenerative Diseases. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 3.0). Gefördert von: Ministry of Science and Technology, Taiwan, National Tsing Hua University, Chang Gung University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A 3D neural spheroid-based system with an interstitial level of flow for simulating the brain microenvironment toward a dynamic amyloid-β induced neuronal toxic model was established. A real-time impedance recording was used to monitor the neural network formation and disconnection.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Neural Stem CellsNeurodegenerative DiseasesHumansAmyloid beta-PeptidesLab-On-A-Chip DevicesNeurons

Substanzen

Amyloid beta-Peptides

Autor:innen und Institutionen

  • Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, No. 101, Section 2, Kuang-Fu Road, Hsinchu 300044, Taiwan. iclee@mx.nthu.edu.tw.
  • Department of Chemical and Biomolecular Engineering, University of Maryland, College Park, Maryland, 20742, USA.

ORCID-Profile: Chu-Chun Liang, Po-Yen Chen, I-Chi Lee

Förderung

  • Ministry of Science and Technology, Taiwan
  • National Tsing Hua University
  • Chang Gung University
  • University of Maryland

Zitieren

APA

Liang, C. C., Chen, P. Y., Liu, N. C., & Lee, I. C. (2024). Comparison between dynamic versus static models and real-time monitoring of neuronal dysfunction in an amyloid-β induced neuronal toxic model on a chip platform. Lab on a Chip. https://doi.org/10.1039/d3lc00507k

Vancouver

Liang CC, Chen PY, Liu NC, Lee IC. Comparison between dynamic versus static models and real-time monitoring of neuronal dysfunction in an amyloid-β induced neuronal toxic model on a chip platform. Lab on a Chip. 2024. doi:10.1039/d3lc00507k

BibTeX
@article{Liang2024,
  author = {Liang, Chu-Chun and Chen, Po-Yen and Liu, Nien-Che and Lee, I-Chi},
  title = {Comparison between dynamic versus static models and real-time monitoring of neuronal dysfunction in an amyloid-β induced neuronal toxic model on a chip platform},
  journal = {Lab on a Chip},
  year = {2024},
  doi = {10.1039/d3lc00507k}
}
Kostenlos starten →