Fachartikel in der Zeitschrift The Analyst, 2023. Verfasst von Varun V Gadkari und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, University of Michigan, Ann Arbor, Michigan 48109, USA. bruotolo@umich.edu. Hauptthemen laut MEDLINE: Proteins, Protein Unfolding. Die Arbeit wurde bisher 21-mal zitiert (Crossref) und nennt 53 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIGMS NIH HHS, NICHD NIH HHS, National Institute of General Medical Sciences.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Collision induced unfolding (CIU) is a potentially transformative method for biomolecular stability assays. Here, we carry out a rigorous inter-laboratory evaluation of CIU, identifying an instrument design that enables reproduceable measurements.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ProteinsProtein UnfoldingHumansReproducibility of ResultsMass SpectrometryIons

Substanzen

ProteinsIons

Autor:innen und Institutionen

  • Department of Chemistry, University of Michigan, Ann Arbor, Michigan 48109, USA. bruotolo@umich.edu.
  • Department of Chemistry, Texas A&M University, College Station, Texas 77843, USA.
  • Center for Innovative Technology, Department of Chemistry, Vanderbilt Institute of Chemical Biology, Vanderbilt Institute for Integrative Biosystems Research and Education, Vanderbilt-Ingram Cancer Center, Vanderbilt Un…
  • Agilent Technologies Inc., Santa Clara, California 95051, USA.

Förderung

  • NIGMS NIH HHS
  • NICHD NIH HHS
  • National Institute of General Medical Sciences
  • Agilent Technologies
  • National Institute of Child Health and Human Development

Zitieren

APA

Gadkari, V. V., Juliano, B. R., Mallis, C. S., May, J. C., Kurulugama, R. T., Fjeldsted, J. C., McLean, J. A., Russell, D. H., & Ruotolo, B. T. (2023). Performance evaluation of in-source ion activation hardware for collision-induced unfolding of proteins and protein complexes on a drift tube ion mobility-mass spectrometer. The Analyst. https://doi.org/10.1039/d2an01452a

Vancouver

Gadkari VV, Juliano BR, Mallis CS, May JC, Kurulugama RT, Fjeldsted JC, et al. Performance evaluation of in-source ion activation hardware for collision-induced unfolding of proteins and protein complexes on a drift tube ion mobility-mass spectrometer. The Analyst. 2023. doi:10.1039/d2an01452a

BibTeX
@article{Gadkari2023,
  author = {Gadkari, Varun V and Juliano, Brock R and Mallis, Christopher S and May, Jody C and Kurulugama, Ruwan T and Fjeldsted, John C and McLean, John A and Russell, David H and Ruotolo, Brandon T},
  title = {Performance evaluation of in-source ion activation hardware for collision-induced unfolding of proteins and protein complexes on a drift tube ion mobility-mass spectrometer},
  journal = {The Analyst},
  year = {2023},
  doi = {10.1039/d2an01452a}
}
Kostenlos starten →