Rapid detection and quantification of glyphosate in water using a handheld portable biosensor
Scientific Reports · 11.04.2026 · 16 (1)
DOI: 10.1038/s41598-026-44827-4 ↗Kurz gefasst
Fachartikel in der Zeitschrift Scientific Reports, online erschienen am 11.04.2026. Verfasst von Andreea Stroia und 8 weiteren Autor:innen. Beteiligte Einrichtung: Wellcome Centre for Integrative Parasitology, Institute of Infection, Immunity and Inflammation, University of Glasgow, Glasgow, G12 8TA, UK. Hauptthemen laut MEDLINE: Glycine, Biosensing Techniques, Herbicides, Water Pollutants, Chemical. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 60 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: EPSRC, Wellcome Trust.
Abstract (Originalsprache)
Glyphosate is the most extensively applied systemic herbicide worldwide, yet its safety remains under scrutiny, with ongoing investigations into potential carcinogenicity. Epidemiological studies associate chronic glyphosate exposure with elevated risks of non-Hodgkin lymphoma and possible endocrine disruption, emphasizing the need for sensitive detection methods. Here, we report a handheld enzymatic biosensor, GlyphoSense Chip, for direct, rapid detection of underivatized glyphosate in drinking water. The device integrates a photodiode-based CMOS chip with an engineered glyphosate N -acetyltransferase and a colorimetric reaction, achieving a sensitivity of 38 µV·mL µg −1 ·s −1 and quantification within one minute. Biosensor response was linear over 0.016–12.5 µg mL −1 ( R 2 = 0.993) with a detection limit of 0.028 µg mL −1 . Recovery analysis in fortified tap water yielded relative standard errors of 1.2–5.8%, and results were statistically indistinguishable from quantitative mass spectrometry ( p > 0.05). This work establishes a robust, field-deployable platform for glyphosate monitoring in water resource safety applications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Wellcome Centre for Integrative Parasitology, Institute of Infection, Immunity and Inflammation, University of Glasgow, Glasgow, G12 8TA, UK.
- Electronics and Nanoscale Engineering, James Watt School of Engineering, University of Glasgow, Glasgow, G12 8LT, UK.
- ASML Veldhoven, De Run 6501, Veldhoven, 5504 DR, The Netherlands.
- School of Physics, Engineering and Technology, University of York, Heslington, York, YO10 5DD, UK.
- York Biomedical Research Institute, University of York, Heslington, York, YO10 5NG, UK.
- Center for Nano Science and Technology, Istituto Italiano di Tecnologia, Milan, 20134, Italy.
Förderung
- EPSRC
- Wellcome Trust
Zitieren
APA
Stroia, A., Cheah, B. C., Patil, S. B., Annese, V. F., Spiess, R., Busche, C., Cumming, D. R. S., Barrett, M. P., & Dheeman, D. S. (2026). Rapid detection and quantification of glyphosate in water using a handheld portable biosensor. Scientific Reports, 16(1). https://doi.org/10.1038/s41598-026-44827-4
Vancouver
Stroia A, Cheah BC, Patil SB, Annese VF, Spiess R, Busche C, et al. Rapid detection and quantification of glyphosate in water using a handheld portable biosensor. Scientific Reports. 2026;16(1). doi:10.1038/s41598-026-44827-4
BibTeX
@article{Stroia2026,
author = {Stroia, Andreea and Cheah, Boon Chong and Patil, Samadhan B and Annese, Valerio F and Spiess, Reynard and Busche, Christoph and Cumming, David R S and Barrett, Michael P and Dheeman, Dharmendra S},
title = {Rapid detection and quantification of glyphosate in water using a handheld portable biosensor},
journal = {Scientific Reports},
year = {2026},
volume = {16},
number = {1},
doi = {10.1038/s41598-026-44827-4}
}
EUVIMED