EUVIMEDEUVIMED entdecken
VergleichsstudieValidierungsstudieOpen Access · CC BY-NC-ND 4.0

Automated measurement of hallux valgus angles using a deep learning model: validation and comparison with surgeons of varying expertise

Qiong Wang, Jun-Hu Wang, Dong-Dong Ji, Yan Zhang, Hong-Mou Zhao

Scientific Reports · 2026

DOI: 10.1038/s41598-026-42100-2 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Scientific Reports, 2026. Verfasst von Qiong Wang und 4 weiteren Autor:innen. Beteiligte Einrichtung: Foot and Ankle Surgery Department, Honghui Hospital, Xi'an Jiaotong University, No. 76 Nanguo Road, Xi'an, 710054, People's Republic of China. Hauptthemen laut MEDLINE: Deep Learning, Hallux Valgus, Image Processing, Computer-Assisted, Radiography. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Xi'an Municipal Health Commission, Xi’an Municipal Health Commission.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Hallux valgus (HV) assessment commonly relies on measuring the hallux valgus angle (HVA) and intermetatarsal angle (IMA) on weight-bearing radiographs. Manual measurement is time-consuming and subject to intra- and inter-observer variability. Deep learning (DL) methods may automate angle measurement with high accuracy, but prior studies often lacked control groups and comparisons across surgeon experience levels. We developed a DL model based on UNet++ with a MobileNetV2 backbone to segment bone axes, followed by a linear regression module to predict HVA and IMA. The dataset comprised 2,468 weight-bearing radiographs (1,920 HV; 548 control) from 2,124 participants. Performance metrics included mean absolute error (MAE), root mean squared error (RMSE), intraclass correlation coefficient (ICC), and outlier rates; model results were compared with measurements from two foot and ankle surgeons of differing experience. In the HV group, the model achieved ICCs of 0.902 for HVA and 0.887 for IMA; in the control group, ICCs were 0.821 (HVA) and 0.898 (IMA). For IMA, the model demonstrated lower MAE and fewer outliers than the surgeons (HV outliers 4.6% vs. 6.6-7.9%; control 4.8% vs. 6.0-9.5%). Average measurement time was 0.13 s per radiograph for the model versus 1.8-2.6 min manually. The proposed DL model automates HVA and IMA measurement with accuracy and reliability comparable to experienced surgeons while markedly improving efficiency. The model also showed consistent performance across HV and control radiographs in our cohort, supporting potential clinical application pending external validation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Deep LearningHallux ValgusImage Processing, Computer-AssistedRadiographyAdultAgedFemaleHumansMaleMiddle AgedCross-Sectional StudiesObserver VariationOrthopedic SurgeonsSurgeons

Stichwörter der Autor:innen

Deep learningHVAHallux valgusIMAWeight-bearing radiograph

Autor:innen und Institutionen

  • Foot and Ankle Surgery Department, Honghui Hospital, Xi'an Jiaotong University, No. 76 Nanguo Road, Xi'an, 710054, People's Republic of China.
  • Diabetic Foot MDT Center, Honghui Hospital, Xi'an Jiaotong University, Xi'an, 710054, People's Republic of China.
  • Xi'an Medical University, No. 1, Xinwang Road, Weiyang District, Xi'an, 710021, People's Republic of China.
  • Foot and Ankle Surgery Department, Honghui Hospital, Xi'an Jiaotong University, No. 76 Nanguo Road, Xi'an, 710054, People's Republic of China. zhao_hongmou@hotmail.com.
  • Diabetic Foot MDT Center, Honghui Hospital, Xi'an Jiaotong University, Xi'an, 710054, People's Republic of China. zhao_hongmou@hotmail.com.

Förderung

  • Xi'an Municipal Health Commission
  • Xi’an Municipal Health Commission

Zitieren

APA

Wang, Q., Wang, J. H., Ji, D. D., Zhang, Y., & Zhao, H. M. (2026). Automated measurement of hallux valgus angles using a deep learning model: validation and comparison with surgeons of varying expertise. Scientific Reports. https://doi.org/10.1038/s41598-026-42100-2

Vancouver

Wang Q, Wang JH, Ji DD, Zhang Y, Zhao HM. Automated measurement of hallux valgus angles using a deep learning model: validation and comparison with surgeons of varying expertise. Scientific Reports. 2026. doi:10.1038/s41598-026-42100-2

BibTeX
@article{Wang2026,
  author = {Wang, Qiong and Wang, Jun-Hu and Ji, Dong-Dong and Zhang, Yan and Zhao, Hong-Mou},
  title = {Automated measurement of hallux valgus angles using a deep learning model: validation and comparison with surgeons of varying expertise},
  journal = {Scientific Reports},
  year = {2026},
  doi = {10.1038/s41598-026-42100-2}
}
Kostenlos starten →