Predictors of optimal angiographic lesion outcomes in drug-coated balloon treatment for de novo coronary artery disease
Scientific Reports · 18.03.2025 · 15 (1)
DOI: 10.1038/s41598-025-92052-2 ↗Kurz gefasst
Fachartikel in der Zeitschrift Scientific Reports, online erschienen am 18.03.2025. Verfasst von Dong Oh Kang und 10 weiteren Autor:innen. Beteiligte Einrichtung: Cardiovascular Center, Department of Internal Medicine, Korea University Guro Hospital, Korea University College of Medicine, Seoul, South Korea. Hauptthemen laut MEDLINE: Angioplasty, Balloon, Coronary, Coronary Angiography, Coronary Artery Disease. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: National Research Foundation of Korea, Korea University Grant.
Abstract (Originalsprache)
Drug-coated balloon (DCB) treatment is an emerging strategy for de novo coronary artery disease (CAD), but procedural optimization remains uncertain. This study analyzed 317 patients who underwent DCB-based intervention for de novo CAD and angiographic follow-up: SR (successful, stent-like result: diameter stenosis < 20% at follow-up angiography, n = 84, 93 lesions) and Non-SR (n = 224, 358 lesions) groups. Baseline clinical and lesion characteristics were similar, except that SR lesions had larger diameter. In SR lesions, specialty balloons were more frequently utilized (p = 0.025), and maximal balloon diameter and balloon-to-artery ratio were significantly greater compared to Non-SR lesions (p < 0.001 and p = 0.008). At a median 8-month follow-up, SR lesions exhibited larger minimal luminal diameter (MLD) and lower late lumen loss, with negative values indicating positive vessel remodeling. In multivariate analysis, post-DCB MLD (odds ratio 1.17 per 0.1 mm increase, p < 0.001) and balloon-to-artery ratio (odds ratio 1.43 per 0.1 increase, p = 0.002) were independent predictors for successful angiographic outcomes with thresholds of 1.95 mm for post-DCB MLD and 1.13 for balloon-to-artery ratio. In 47 patients, IVUS guidance resulted in balloon-to-artery ratio of 1.23 as calculated by QCA. The study demonstrated the importance of achieving maximal post-DCB MLD through aggressive lesion predilation, underscoring the need for refining procedural strategies. NCT04619277 (Impact of Drug-Coated Balloon Treatment in De Novo Coronary Lesion).
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Cardiovascular Center, Department of Internal Medicine, Korea University Guro Hospital, Korea University College of Medicine, Seoul, South Korea.
- Cardiovascular Center, Department of Internal Medicine, Korea University Ansan Hospital, Korea University College of Medicine, 123, Jeokgeum-ro, Danwon-gu, Ansan-si, Gyeonggi-do, 15355, South Korea.
- Department of Cardiology, Ulsan University Hospital, University of Ulsan College of Medicine, 877 Bangeojinsunhwan-doro, Dong-gu, Ulsan, 44033, South Korea.
- Division of Cardiology, Department of Internal Medicine, Kangwon National University School of Medicine, Chuncheon, South Korea.
- Department of Cardiology, Ulsan University Hospital, University of Ulsan College of Medicine, 877 Bangeojinsunhwan-doro, Dong-gu, Ulsan, 44033, South Korea. sesim1989@gmail.com.
- Cardiovascular Center, Department of Internal Medicine, Korea University Ansan Hospital, Korea University College of Medicine, 123, Jeokgeum-ro, Danwon-gu, Ansan-si, Gyeonggi-do, 15355, South Korea. sunwon11@hanmail.net.
Förderung
- National Research Foundation of Korea
- Korea University Grant
Zitieren
APA
Kang, D. O., Lee, J. S., Kim, B., Kim, Y. H., Lim, S. Y., Kim, S. H., Ahn, J. C., Her, A. Y., Song, W. H., Shin, E. S., & Kim, S. (2025). Predictors of optimal angiographic lesion outcomes in drug-coated balloon treatment for de novo coronary artery disease. Scientific Reports, 15(1). https://doi.org/10.1038/s41598-025-92052-2
Vancouver
Kang DO, Lee JS, Kim B, Kim YH, Lim SY, Kim SH, et al. Predictors of optimal angiographic lesion outcomes in drug-coated balloon treatment for de novo coronary artery disease. Scientific Reports. 2025;15(1). doi:10.1038/s41598-025-92052-2
BibTeX
@article{Kang2025,
author = {Kang, Dong Oh and Lee, Jong-Seok and Kim, Bitna and Kim, Yong-Hyun and Lim, Sang-Yup and Kim, Seong Hwan and Ahn, Jeong-Cheon and Her, Ae-Young and Song, Woo-Hyuk and Shin, Eun-Seok and Kim, Sunwon},
title = {Predictors of optimal angiographic lesion outcomes in drug-coated balloon treatment for de novo coronary artery disease},
journal = {Scientific Reports},
year = {2025},
volume = {15},
number = {1},
doi = {10.1038/s41598-025-92052-2}
}