Automated Global Positioning Layout (GPL) for accuracy assessment in CAD-CAM mandibular reconstruction – Method validation
Scientific Reports · 2026
DOI: 10.1038/s41598-025-30516-1 ↗Kurz gefasst
Fachartikel in der Zeitschrift Scientific Reports, 2026. Verfasst von Elisa Vargiu und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Management and Engineering, University of Padua, Padua, Italy. elisa.vargiu@phd.unipd.it. Hauptthemen laut MEDLINE: Computer-Aided Design, Mandibular Reconstruction, Surgery, Computer-Assisted, Mandible. Die Arbeit nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
The lack of a standardized methodology complicates accuracy assessment in computer-assisted mandibular reconstruction. Existing landmark-based methods are susceptible to operator variability, while surface-based comparisons can mask local deviations. This study validates a novel, automated protocol, the Global Positioning Layout (GPL), to quantify the 3D discrepancy between the virtual surgical plan and the postoperative outcome, by comparing its performance and reliability against Methods A and B. A retrospective cohort of 17 patients was analysed, with three operators performing all measurements on two occasions. The GPL method demonstrated complete reproducibility, with no inter- or intra-operator variability, providing a detailed, spatially-oriented assessment of deviations. In contrast, the landmark-based method showed poor reproducibility and systematic bias and was often inapplicable due to the absence of landmarks after resection. The surface-based method, while objective for its mean error metric, was operator-dependent for initial alignment and its non-directional output masked significant localized deviations. This study validates GPL as a robust and fully reproducible tool that overcomes the critical limitations of established techniques. The GPL method provides a strong foundation for a standardized protocol, essential for the reliable comparison of surgical outcomes, refinement of surgical techniques, and improvement of long-term patient outcomes.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Management and Engineering, University of Padua, Padua, Italy. elisa.vargiu@phd.unipd.it.
- Maxillo-Facial Surgery Unit, Head and Neck Department, University Hospital of Parma, Parma, Italy.
- Maxillofacial Surgery Unit, ''S. Anna'' Hospital, Como, Italy.
- Department of Clinical Orthopaedics, University of Florence, A.O.U Careggi CTO Florence, Florence, Italy.
- Department of Neuroscience, Unit of Maxillofacial Surgery, University of Padua, Padua, Italy.
- Department of Medical and Surgical Sciences, Alma Mater Studiorum- University of Bologna, Bologna, Italy.
Zitieren
APA
Vargiu, E., Tognin, L., Bettini, G., Menapace, G., Franco, P., Saia, G., Bedogni, G., Meneghello, R., & Bedogni, A. (2026). Automated Global Positioning Layout (GPL) for accuracy assessment in CAD-CAM mandibular reconstruction – Method validation. Scientific Reports. https://doi.org/10.1038/s41598-025-30516-1
Vancouver
Vargiu E, Tognin L, Bettini G, Menapace G, Franco P, Saia G, et al. Automated Global Positioning Layout (GPL) for accuracy assessment in CAD-CAM mandibular reconstruction – Method validation. Scientific Reports. 2026. doi:10.1038/s41598-025-30516-1
BibTeX
@article{Vargiu2026,
author = {Vargiu, Elisa and Tognin, Laura and Bettini, Giordana and Menapace, Giorgia and Franco, Piero and Saia, Giorgia and Bedogni, Giorgio and Meneghello, Roberto and Bedogni, Alberto},
title = {Automated Global Positioning Layout (GPL) for accuracy assessment in CAD-CAM mandibular reconstruction – Method validation},
journal = {Scientific Reports},
year = {2026},
doi = {10.1038/s41598-025-30516-1}
}
EUVIMED