Improving quality control of whole slide images by explicit artifact augmentation
Scientific Reports · 01.08.2024 · 14 (1)
DOI: 10.1038/s41598-024-68667-2 ↗Kurz gefasst
Fachartikel in der Zeitschrift Scientific Reports, online erschienen am 01.08.2024. Verfasst von Artur Jurgas und 5 weiteren Autor:innen. Beteiligte Einrichtung: AGH University of Krakow, Faculty of Electrical Engineering, Automatics, Computer Science and Biomedical Engineering, 30059, Krakow, Poland. arjurgas…. Hauptthemen laut MEDLINE: Artifacts, Quality Control, Algorithms, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Infrastruktura PL-Grid, Horizon 2020, Innovative Medicines Initiative 2.
Abstract (Originalsprache)
The problem of artifacts in whole slide image acquisition, prevalent in both clinical workflows and research-oriented settings, necessitates human intervention and re-scanning. Overcoming this challenge requires developing quality control algorithms, that are hindered by the limited availability of relevant annotated data in histopathology. The manual annotation of ground-truth for artifact detection methods is expensive and time-consuming. This work addresses the issue by proposing a method dedicated to augmenting whole slide images with artifacts. The tool seamlessly generates and blends artifacts from an external library to a given histopathology dataset. The augmented datasets are then utilized to train artifact classification methods. The evaluation shows their usefulness in classification of the artifacts, where they show an improvement from 0.10 to 0.01 AUROC depending on the artifact type. The framework, model, weights, and ground-truth annotations are freely released to facilitate open science and reproducible research.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- AGH University of Krakow, Faculty of Electrical Engineering, Automatics, Computer Science and Biomedical Engineering, 30059, Krakow, Poland. arjurgas@agh.edu.pl.
- University of Applied Sciences Western Switzerland (HES-SO), Institute of Informatics, 3960, Sierre, Switzerland. arjurgas@agh.edu.pl.
- AGH University of Krakow, Faculty of Electrical Engineering, Automatics, Computer Science and Biomedical Engineering, 30059, Krakow, Poland.
- University of Applied Sciences Western Switzerland (HES-SO), Institute of Informatics, 3960, Sierre, Switzerland.
- Radboud University Medical Center, Nijmegen, The Netherlands.
- Department of Neuroscience, University of Padova, Padua, Italy.
Förderung
- Infrastruktura PL-Grid
- Horizon 2020, Innovative Medicines Initiative 2
Zitieren
APA
Jurgas, A., Wodzinski, M., D'Amato, M., van der Laak, J., Atzori, M., & Müller, H. (2024). Improving quality control of whole slide images by explicit artifact augmentation. Scientific Reports, 14(1). https://doi.org/10.1038/s41598-024-68667-2
Vancouver
Jurgas A, Wodzinski M, D'Amato M, van der Laak J, Atzori M, Müller H. Improving quality control of whole slide images by explicit artifact augmentation. Scientific Reports. 2024;14(1). doi:10.1038/s41598-024-68667-2
BibTeX
@article{Jurgas2024,
author = {Jurgas, Artur and Wodzinski, Marek and D'Amato, Marina and van der Laak, Jeroen and Atzori, Manfredo and Müller, Henning},
title = {Improving quality control of whole slide images by explicit artifact augmentation},
journal = {Scientific Reports},
year = {2024},
volume = {14},
number = {1},
doi = {10.1038/s41598-024-68667-2}
}
EUVIMED