EUVIMEDEUVIMED entdecken
ValidierungsstudieOpen Access · CC BY 4.0

Design and validation of a wearable dynamometry system for knee extension-flexion torque measurement

Sungwoo Park, Youho Myong, Minwoo Cho, Seung Yeon Cho, Woo Hyung Lee, Byung-Mo Oh, Sungwan Kim

Scientific Reports · 07.05.2024 · 14 (1)

DOI: 10.1038/s41598-024-60985-9 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift Scientific Reports, online erschienen am 07.05.2024. Verfasst von Sungwoo Park und 6 weiteren Autor:innen. Beteiligte Einrichtung: Interdisciplinary Program in Bioengineering, The Graduate School, Seoul National University, 1 Gwanak-ro, Gwanak-gu, Seoul, 08826, Republic of Korea. Hauptthemen laut MEDLINE: Muscle Strength Dynamometer, Wearable Electronic Devices, Knee Joint, Torque. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Seoul National University, Seoul National University Hospital, National Research Foundation of Korea.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Muscle strength assessments are vital in rehabilitation, orthopedics, and sports medicine. However, current methods used in clinical settings, such as manual muscle testing and hand-held dynamometers, often lack reliability, and isokinetic dynamometers (IKD), while reliable, are not easily portable. The aim of this study was to design and validate a wearable dynamometry system with high accessibility, accuracy, and reliability, and to validate the device. Therefore, we designed a wearable dynamometry system (WDS) equipped with knee joint torque sensors. To validate this WDS, we measured knee extension and flexion strength in 39 healthy adults using both the IKD and WDS. Comparing maximal isometric torque measurements, WDS and IKD showed strong correlation and good reliability for extension (Pearson’s r: 0.900; intraclass correlation coefficient [ICC]: 0.893; standard error of measurement [SEM]: 9.85%; minimal detectable change [MDC]: 27.31%) and flexion (Pearson’s r: 0.870; ICC: 0.857; SEM: 11.93%; MDC: 33.07%). WDS demonstrated excellent inter-rater (Pearson’s r: 0.990; ICC: 0.993; SEM: 4.05%) and test–retest (Pearson’s r: 0.970; ICC: 0.984; SEM: 6.15%) reliability during extension/flexion. User feedback from 35 participants, including healthcare professionals, underscores WDS's positive user experience and clinical potential. The proposed WDS is a suitable alternative to IKD, providing high accuracy, reliability, and potentially greater accessibility.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Muscle Strength DynamometerWearable Electronic DevicesKnee JointTorqueMuscle StrengthHumansMaleAdultFemaleReproducibility of ResultsRange of Motion, ArticularYoung AdultEquipment Design

Autor:innen und Institutionen

  • Interdisciplinary Program in Bioengineering, The Graduate School, Seoul National University, 1 Gwanak-ro, Gwanak-gu, Seoul, 08826, Republic of Korea.
  • Innovative Medical Technology Research Institute, Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, Seoul, 03080, Republic of Korea.
  • Department of Biomedical Engineering, Seoul National University College of Medicine, 103 Daehak-ro, Jongno-gu, Seoul, 03080, Republic of Korea.
  • Department of Rehabilitation Medicine, Seoul National University Hospital, Seoul National University College of Medicine, 101 Daehak-ro, Jongno-gu, Seoul, 03080, Republic of Korea.
  • Department of Transdisciplinary Medicine, Seoul National University Hospital, 101 Daehak-ro, Jongno gu, Seoul, 03080, Republic of Korea.
  • Department of Rehabilitation Medicine, Seoul National University Hospital, Seoul National University College of Medicine, 101 Daehak-ro, Jongno-gu, Seoul, 03080, Republic of Korea. moya1@snu.ac.kr.

Förderung

  • Seoul National University
  • Seoul National University Hospital
  • National Research Foundation of Korea

Zitieren

APA

Park, S., Myong, Y., Cho, M., Cho, S. Y., Lee, W. H., Oh, B. M., & Kim, S. (2024). Design and validation of a wearable dynamometry system for knee extension-flexion torque measurement. Scientific Reports, 14(1). https://doi.org/10.1038/s41598-024-60985-9

Vancouver

Park S, Myong Y, Cho M, Cho SY, Lee WH, Oh BM, et al. Design and validation of a wearable dynamometry system for knee extension-flexion torque measurement. Scientific Reports. 2024;14(1). doi:10.1038/s41598-024-60985-9

BibTeX
@article{Park2024,
  author = {Park, Sungwoo and Myong, Youho and Cho, Minwoo and Cho, Seung Yeon and Lee, Woo Hyung and Oh, Byung-Mo and Kim, Sungwan},
  title = {Design and validation of a wearable dynamometry system for knee extension-flexion torque measurement},
  journal = {Scientific Reports},
  year = {2024},
  volume = {14},
  number = {1},
  doi = {10.1038/s41598-024-60985-9}
}
Kostenlos starten →