An action research study of quality improvement in instrument packaging procedures for the central sterile supply department

Wei Pan, Liangying Yi, Ting Hu, Juanli Huang, Yongdeng Huang

Scientific Reports · 2024

DOI: 10.1038/s41598-024-54237-z ↗

Kurz gefasst

Fachartikel in der Zeitschrift Scientific Reports, 2024. Verfasst von Wei Pan und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Sterile Processing Nursing, West China Second University Hospital, Sichuan University, Chengdu, Sichuan, China. Hauptthemen laut MEDLINE: Sterilization, Quality Improvement. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Science and Technology Department of Sichuan Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study aimed to reduce instrument packaging defects in the Central Sterile Supply Department (CSSD) using action research. Data of the instrument packs packaged by the packaging personnel at the CSSD of the authors’ institution during March to May 2023 were collected and analyzed. After identifying the problems, 2 rounds of cyclic process of “plan-action-observe-reflect” were implemented to standardize the packaging procedures and develop and improve the applicable check of standard operating procedures for the CSSD. After strictly implementing the packaging operation standards and checklists, the number of packaging defect cases dropped from 274 to 41. A significant difference was identified between the number of packaging personnel who achieved a “pass” in the assessment of 3 items for maintenance. Also, 1 item for assembly had significant differences compared with the baseline number after the first cycle ( P ≤ 0.001). A significant difference was identified between the number of packaging personnel who achieved a “pass” in the assessment of 20 items for 6 components after the second cycle compared with that after the first cycle ( P ≤ 0.05). Through action research methodology, strict implementation of standardized packaging procedures in the CSSD can reduce packaging defects, thereby decreasing clinical complaints and ensuring patient safety.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SterilizationQuality ImprovementHumansProduct PackagingDrug PackagingHealth Facilities

Stichwörter der Autor:innen

Equipment failurePatient safetyProduct packagingSurgical instruments

Autor:innen und Institutionen

  • Department of Sterile Processing Nursing, West China Second University Hospital, Sichuan University, Chengdu, Sichuan, China.
  • Key Laboratory of Birth Defects and Related Diseases of Women and Children (Sichuan University), Ministry of Education, Chengdu, Sichuan, China.
  • Department of Sterile Processing Nursing, West China Second University Hospital, Sichuan University, Chengdu, Sichuan, China. yiliangying88@163.com.
  • Key Laboratory of Birth Defects and Related Diseases of Women and Children (Sichuan University), Ministry of Education, Chengdu, Sichuan, China. yiliangying88@163.com.

Förderung

  • Science and Technology Department of Sichuan Province

Zitieren

APA

Pan, W., Yi, L., Hu, T., Huang, J., & Huang, Y. (2024). An action research study of quality improvement in instrument packaging procedures for the central sterile supply department. Scientific Reports. https://doi.org/10.1038/s41598-024-54237-z

Vancouver

Pan W, Yi L, Hu T, Huang J, Huang Y. An action research study of quality improvement in instrument packaging procedures for the central sterile supply department. Scientific Reports. 2024. doi:10.1038/s41598-024-54237-z

BibTeX
@article{Pan2024,
  author = {Pan, Wei and Yi, Liangying and Hu, Ting and Huang, Juanli and Huang, Yongdeng},
  title = {An action research study of quality improvement in instrument packaging procedures for the central sterile supply department},
  journal = {Scientific Reports},
  year = {2024},
  doi = {10.1038/s41598-024-54237-z}
}
Kostenlos starten →