EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Dissecting the vascular-cognitive nexus: energetic vs. conventional hemodynamic parameters

Hao-Min Cheng, Jiun-Jr Wang, Shao-Yuan Chuang, Chen-Hua Lin, Gary F Mitchell, Chi-Jung Huang, Pei-Ning Wang, Chih-Ping Chung, Liang-Kung Chen, Wen-Harn Pan, Li-Ning Peng, Chen-Huan Chen

Hypertension Research · 2024

DOI: 10.1038/s41440-024-01735-2 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Hypertension Research, 2024. Verfasst von Hao-Min Cheng und 11 weiteren Autor:innen. Beteiligte Einrichtung: Division of Faculty Development, Taipei Veterans General Hospital, Taipei, Taiwan, ROC. hmcheng@vghtpe.gov.tw. Hauptthemen laut MEDLINE: Hemodynamics, Cognition. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Blood pressure or flow measurements have been associated with vascular health and cognitive function. We proposed that energetic hemodynamic parameters may provide a more nuanced understanding and stronger correlation with cognitive function, in comparisons with conventional aortic and carotid pressure and flow parameters. The study comprised 1858 participants, in whom we assessed cognitive function via MoCA method, and measured central aortic and carotid pressure and flow waveforms. In addition to various pressure and flow parameters, we calculated energetic hemodynamic parameters through integration of pressure multiplying flow with respect to time. Energetic hemodynamic parameters, particularly aortic and carotid mean and pulsatile energy and pulsatility index (PI), were significantly associated with MoCA score more than any aortic and carotid pressure and flow parameters, after adjusting for age, sex, education, depression score, heart rate, BMI, HDL-cholesterol, and glucose levels. MoCA exhibited a strong positive relationship with carotid mean energy (standardized beta = 0.053, P = 0.0253) and a negative relationship with carotid energy PI (standardized beta = −0.093, P = 0.0002), exceeding the association with all traditional pressure- or flow-based parameters. Aortic pressure reflection coefficient at the aorto-carotid junction was positively correlated with mean carotid energy and negatively correlated with PI. Aortic characteristic impedance positively correlated with carotid energy PI but not mean energy. Our research indicates that energetic hemodynamic parameters, particularly carotid mean energy and carotid energy PI, have a stronger association with MoCA scores than traditional pressure- or flow-based metrics. This correlation with cognitive function is notably influenced by the properties of the aorto-carotid interface.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

HemodynamicsCognitionHumansFemaleMaleMiddle AgedAgedBlood PressureCarotid ArteriesAortaAdultPulsatile Flow

Stichwörter der Autor:innen

Carotid pulsatile energyCognitive functionFlow pulsatility indexHigh blood pressurePressure pulsatility index

Autor:innen und Institutionen

  • Division of Faculty Development, Taipei Veterans General Hospital, Taipei, Taiwan, ROC. hmcheng@vghtpe.gov.tw.
  • Department of Medical Education, Taipei Veterans General Hospital, Taipei, Taiwan, ROC. hmcheng@vghtpe.gov.tw.
  • Institute of Public Health and Cardiovascular Research Center, National Yang Ming Chiao Tung University College of Medicine, Taipei, Taiwan, ROC. hmcheng@vghtpe.gov.tw.
  • School of Medicine, Fu Jen Catholic University, New Taipei City, Taiwan, ROC.
  • Institute of Population Health Science, National Health Research Institute, Miaoli, Taiwan, ROC.
  • Institute of Public Health and Cardiovascular Research Center, National Yang Ming Chiao Tung University College of Medicine, Taipei, Taiwan, ROC.

Zitieren

APA

Cheng, H. M., Wang, J. J., Chuang, S. Y., Lin, C. H., Mitchell, G. F., Huang, C. J., Wang, P. N., Chung, C. P., Chen, L. K., Pan, W. H., Peng, L. N., & Chen, C. H. (2024). Dissecting the vascular-cognitive nexus: energetic vs. conventional hemodynamic parameters. Hypertension Research. https://doi.org/10.1038/s41440-024-01735-2

Vancouver

Cheng HM, Wang JJ, Chuang SY, Lin CH, Mitchell GF, Huang CJ, et al. Dissecting the vascular-cognitive nexus: energetic vs. conventional hemodynamic parameters. Hypertension Research. 2024. doi:10.1038/s41440-024-01735-2

BibTeX
@article{Cheng2024,
  author = {Cheng, Hao-Min and Wang, Jiun-Jr and Chuang, Shao-Yuan and Lin, Chen-Hua and Mitchell, Gary F and Huang, Chi-Jung and Wang, Pei-Ning and Chung, Chih-Ping and Chen, Liang-Kung and Pan, Wen-Harn and Peng, Li-Ning and Chen, Chen-Huan},
  title = {Dissecting the vascular-cognitive nexus: energetic vs. conventional hemodynamic parameters},
  journal = {Hypertension Research},
  year = {2024},
  doi = {10.1038/s41440-024-01735-2}
}
Kostenlos starten →