EUVIMEDEUVIMED entdecken
MetaanalyseSystematische ÜbersichtOpen Access · CC BY 4.0

Retinal sensitivity changes in early/intermediate AMD: a systematic review and meta-analysis of visual field testing under mesopic and scotopic lighting

Matt Trinh, Michael Kalloniatis, Sieu K Khuu, Lisa Nivison-Smith

Eye · 2024

DOI: 10.1038/s41433-024-03033-0 ↗

Kurz gefasst

Metaanalyse in der Zeitschrift Eye, 2024. Verfasst von Matt Trinh und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Optometry and Vision Science, University of New South Wales, Sydney, NSW, Australia. Hauptthemen laut MEDLINE: Macular Degeneration, Mesopic Vision, Night Vision, Visual Field Tests. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 140 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Department of Health | National Health and Medical Research Council (NHMRC).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Visual fields under mesopic and scotopic lighting are increasingly being used for macular functional assessment. This review evaluates its statistical significance and clinical relevance, and the optimal testing protocol for early/intermediate age-related macular degeneration (AMD). PubMed and Embase were searched from inception to 14/05/2022. All quality assessments were performed according to GRADE guidelines. The primary outcome was global mean sensitivity (MS), further meta-analysed by: AMD classification scheme, device, test pattern, mesopic/scotopic lighting, stimuli size/chromaticity, pupil dilation, testing radius (area), background luminance, adaptation time, AMD severity, reticular pseudodrusen presence, and follow-up visit. From 1489 studies screened, 42 observational study results contributed to the primary meta-analysis. Supported by moderate GRADE certainty of the evidence, global MS was significantly reduced across all devices under mesopic and scotopic lighting with large effect size (−0.9 [−1.04, −0.75] Hedge’s g, P < 0.0001). The device ( P < 0.01) and lighting ( P < 0.05) used were the only modifiable factors affecting global MS, whereby the mesopic MP-1 and MAIA produced the largest effect sizes and exceeded test-retest variabilities. Global MS was significantly affected by AMD severity (intermediate versus early AMD; −0.58 [−0.88, −0.29] Hedge’s g or −2.55 [3.62, −1.47] MAIA-dB) and at follow-up visit (versus baseline; −0.62 [−0.84, −0.41] Hedge’s g or −1.61[−2.69, −0.54] MAIA-dB). Magnitudes of retinal sensitivity changes in early/intermediate AMD are clinically relevant for the MP-1 and MAIA devices under mesopic lighting within the central 10° radius. Other factors including pupil dilation and dark adaptation did not significantly affect global MS in early/intermediate AMD.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Macular DegenerationMesopic VisionNight VisionVisual Field TestsHumansDark AdaptationLightingRetinaVisual Fields

Autor:innen und Institutionen

  • School of Optometry and Vision Science, University of New South Wales, Sydney, NSW, Australia.
  • School of Medicine (Optometry), Deakin University, Geelong, VIC, Australia.
  • School of Optometry and Vision Science, University of New South Wales, Sydney, NSW, Australia. l.nivison-smith@unsw.edu.au.

Förderung

  • Department of Health | National Health and Medical Research Council (NHMRC)

Zitieren

APA

Trinh, M., Kalloniatis, M., Khuu, S. K., & Nivison-Smith, L. (2024). Retinal sensitivity changes in early/intermediate AMD: a systematic review and meta-analysis of visual field testing under mesopic and scotopic lighting. Eye. https://doi.org/10.1038/s41433-024-03033-0

Vancouver

Trinh M, Kalloniatis M, Khuu SK, Nivison-Smith L. Retinal sensitivity changes in early/intermediate AMD: a systematic review and meta-analysis of visual field testing under mesopic and scotopic lighting. Eye. 2024. doi:10.1038/s41433-024-03033-0

BibTeX
@article{Trinh2024,
  author = {Trinh, Matt and Kalloniatis, Michael and Khuu, Sieu K and Nivison-Smith, Lisa},
  title = {Retinal sensitivity changes in early/intermediate AMD: a systematic review and meta-analysis of visual field testing under mesopic and scotopic lighting},
  journal = {Eye},
  year = {2024},
  doi = {10.1038/s41433-024-03033-0}
}
Kostenlos starten →