Picotesla-sensitivity microcavity optomechanical magnetometry
Light: Science & Applications · 29.09.2024 · 13 (1)
DOI: 10.1038/s41377-024-01643-7 ↗Kurz gefasst
Fachartikel in der Zeitschrift Light: Science & Applications, online erschienen am 29.09.2024. Verfasst von Zhi-Gang Hu und 14 weiteren Autor:innen. Beteiligte Einrichtung: Beijing National Laboratory for Condensed Matter Physics, Institute of Physics, Chinese Academy of Sciences, Beijing, 100190, China. Die Arbeit wurde bisher 43-mal zitiert (Crossref) und nennt 64 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Cavity optomechanical systems have enabled precision sensing of magnetic fields, by leveraging the optical resonance-enhanced readout and mechanical resonance-enhanced response. Previous studies have successfully achieved mass-produced and reproducible microcavity optomechanical magnetometry (MCOM) by incorporating Terfenol-D thin films into high-quality ( Q ) factor whispering gallery mode (WGM) microcavities. However, the sensitivity was limited to 585 pT Hz −1/2 , over 20 times inferior to those using Terfenol-D particles. In this work, we propose and demonstrate a high-sensitivity and mass-produced MCOM approach by sputtering a FeGaB thin film onto a high- Q SiO 2 WGM microdisk. Theoretical studies are conducted to explore the magnetic actuation constant and noise-limited sensitivity by varying the parameters of the FeGaB film and SiO 2 microdisk. Multiple magnetometers with different radii are fabricated and characterized. By utilizing a microdisk with a radius of 355 μm and a thickness of 1 μm, along with a FeGaB film with a radius of 330 μm and a thickness of 1.3 μm, we have achieved a remarkable peak sensitivity of 1.68 pT Hz −1/2 at 9.52 MHz. This represents a significant improvement of over two orders of magnitude compared with previous studies employing sputtered Terfenol-D film. Notably, the magnetometer operates without a bias magnetic field, thanks to the remarkable soft magnetic properties of the FeGaB film. Furthermore, as a proof of concept, we have demonstrated the real-time measurement of a pulsed magnetic field simulating the corona current in a high-voltage transmission line using our developed magnetometer. These high-sensitivity magnetometers hold great potential for various applications, such as magnetic induction tomography and corona current monitoring.
Autor:innen und Institutionen
- Beijing National Laboratory for Condensed Matter Physics, Institute of Physics, Chinese Academy of Sciences, Beijing, 100190, China.
- University of Chinese Academy of Sciences, Beijing, 100049, China.
- School of Physics, Beihang University, Beijing, 100191, China.
- Songshan Lake Materials Laboratory, Dongguan, 523808, Guangdong, China.
- Beijing National Laboratory for Condensed Matter Physics, Institute of Physics, Chinese Academy of Sciences, Beijing, 100190, China. yongchang.lau@iphy.ac.cn.
- University of Chinese Academy of Sciences, Beijing, 100049, China. yongchang.lau@iphy.ac.cn.
Zitieren
APA
Hu, Z. G., Gao, Y. M., Liu, J. F., Yang, H., Wang, M., Lei, Y., Zhou, X., Li, J., Cao, X., Liang, J., Hu, C. Q., Li, Z., Lau, Y. C., Cai, J. W., & Li, B. B. (2024). Picotesla-sensitivity microcavity optomechanical magnetometry. Light: Science & Applications, 13(1). https://doi.org/10.1038/s41377-024-01643-7
Vancouver
Hu ZG, Gao YM, Liu JF, Yang H, Wang M, Lei Y, et al. Picotesla-sensitivity microcavity optomechanical magnetometry. Light: Science & Applications. 2024;13(1). doi:10.1038/s41377-024-01643-7
BibTeX
@article{Hu2024,
author = {Hu, Zhi-Gang and Gao, Yi-Meng and Liu, Jian-Fei and Yang, Hao and Wang, Min and Lei, Yuechen and Zhou, Xin and Li, Jincheng and Cao, Xuening and Liang, Jinjing and Hu, Chao-Qun and Li, Zhilin and Lau, Yong-Chang and Cai, Jian-Wang and Li, Bei-Bei},
title = {Picotesla-sensitivity microcavity optomechanical magnetometry},
journal = {Light: Science & Applications},
year = {2024},
volume = {13},
number = {1},
doi = {10.1038/s41377-024-01643-7}
}
EUVIMED