Evaluating Heat Risk: Comparing On‐Site WBGT Measurements Versus Smartphone Application Estimates
GeoHealth · 2025-03 · 9 (3)
DOI: 10.1029/2025gh001347 ↗Kurz gefasst
Fachartikel in der Zeitschrift GeoHealth, online erschienen am 25.03.2025. Verfasst von A J Grundstein und 9 weiteren Autor:innen. Beteiligte Einrichtung: University of Georgia Athens GA USA. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Exertional heat illness poses a significant risk for workers, athletes, and military personnel participating in outdoor activities during hot weather. An important component of heat safety is to monitor environmental conditions through heat stress indices like the wet bulb globe temperature (WBGT) and adjust activity as conditions get progressively hotter. Traditionally, on‐site (OS) WBGT measurement devices are used, but phone applications (PAs) offering WBGT estimates have emerged as a potential alternative. However, there is little information on how closely PA‐derived WBGTs match OS measurements to guide decision‐making. This study compared the PA‐derived Zelus WBGT estimates with OS measurements from Kestrel 5400 devices and their impact on activity modification categorization. A 2‐month observational study collected 1,056 paired (OS and PA) WBGT measurements from 26 high schools across 11 states in the United States and over diverse surfaces (artificial turf 53%, natural grass 44%, others 3%). WBGT values were categorized using regional activity modification thresholds to account for local acclimatization. Our findings indicated that while exhibiting high correlation ( r = 0.89), PA WBGTs were on average about 1°C cooler, with differences of 2–3°C at higher WBGTs. Findings were similar for both grass and artificial turf surfaces. Further, significant discrepancies were observed in WBGT‐based activity modification categories, with the PA more frequently indicating lower modification categories compared to OS devices, especially in hotter conditions. In light of these findings, the PA requires further validation prior to its adoption as a replacement for OS measurements.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- University of Georgia Athens GA USA.
- University of South Carolina Columbia SC USA.
- Duke University Durham NC USA.
- University of South Florida Tampa FL USA.
- Texas State University San Marcos TX USA.
- Arizona State University Phoenix AZ USA.
ORCID-Profile: A J Grundstein, S W Yeargin, E R Cooper, L Cargile, J Clark, R M Lopez, K C Miller, A M Montalvo, S Scarneo-Miller, R L Stearns
Zitieren
APA
Grundstein, A. J., Yeargin, S. W., Cooper, E. R., Cargile, L., Clark, J., Lopez, R. M., Miller, K. C., Montalvo, A. M., Scarneo-Miller, S., & Stearns, R. L. (2025). Evaluating Heat Risk: Comparing On‐Site WBGT Measurements Versus Smartphone Application Estimates. GeoHealth, 9(3). https://doi.org/10.1029/2025gh001347
Vancouver
Grundstein AJ, Yeargin SW, Cooper ER, Cargile L, Clark J, Lopez RM, et al. Evaluating Heat Risk: Comparing On‐Site WBGT Measurements Versus Smartphone Application Estimates. GeoHealth. 2025;9(3). doi:10.1029/2025gh001347
BibTeX
@article{Grundstein2025,
author = {Grundstein, A J and Yeargin, S W and Cooper, E R and Cargile, L and Clark, J and Lopez, R M and Miller, K C and Montalvo, A M and Scarneo-Miller, S and Stearns, R L},
title = {Evaluating Heat Risk: Comparing On‐Site WBGT Measurements Versus Smartphone Application Estimates},
journal = {GeoHealth},
year = {2025},
volume = {9},
number = {3},
doi = {10.1029/2025gh001347}
}
EUVIMED