EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Spectral Contamination of the 6300 Å Emission in Single‐Etalon Fabry‐Perot Interferometers

R. B. Kerr, S. Kapali, B. J. Harding, J. Riccobono, M. A. Migliozzi, J. R. Souza, R. Mesquita, P. Dandenault, Q. Wu, A. A. Pimenta, L. Peres, R. Silva

Journal of Geophysical Research: Space Physics · 2023-09 · 128 (9)

DOI: 10.1029/2023ja031601 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Geophysical Research: Space Physics, online erschienen am 25.09.2023. Verfasst von R. B. Kerr und 11 weiteren Autor:innen. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 61 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: National Science Foundation.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The spectral line profile of the atomic oxygen O 1 D 2 — 3 P 2 transition near 6300 Å in the airglow has been used for more than 50 years to extract neutral wind and temperature information from the F‐region ionosphere. A new spectral model and recent samples of this airglow emission in the presence of the nearby lambda‐doubled OH Meinel (9‐3) P 2 (2.5) emission lines underscores earlier cautions that OH can significantly distort the OI line center position and line width observed using a single‐etalon Fabry‐Perot interferometer (FPI). The consequence of these profile distortions in terms of the emission profile line width and Doppler position is a strong function of the selected etalon plate spacing. Single‐etalon Fabry‐Perot interferometers placed in the field for thermospheric measurements have widely varying etalon spacings, so that systematic wind biases caused by the OH line positions differ between instruments, complicating comparisons between sites. Based on the best current determinations of the OH and O 1 D line positions, the ideal gap for a single‐etalon FPI wind measurements places the OH emissions in the wings of the O 1 D spectral line profile. Optical systems that can accommodate prefilters with square passbands less than ∼3 Å in the optical beam can effectively block the OH contamination. When that is not possible, a method to fit for OH contamination and remove it in the spectral background of an active Fabry‐Perot system is evaluated.

Förderung

  • National Science Foundation

Zitieren

APA

Kerr, R. B., Kapali, S., Harding, B. J., Riccobono, J., Migliozzi, M. A., Souza, J. R., Mesquita, R., Dandenault, P., Wu, Q., Pimenta, A. A., Peres, L., & Silva, R. (2023). Spectral Contamination of the 6300 Å Emission in Single‐Etalon Fabry‐Perot Interferometers. Journal of Geophysical Research: Space Physics, 128(9). https://doi.org/10.1029/2023ja031601

Vancouver

Kerr RB, Kapali S, Harding BJ, Riccobono J, Migliozzi MA, Souza JR, et al. Spectral Contamination of the 6300 Å Emission in Single‐Etalon Fabry‐Perot Interferometers. Journal of Geophysical Research: Space Physics. 2023;128(9). doi:10.1029/2023ja031601

BibTeX
@article{Kerr2023,
  author = {Kerr, R. B. and Kapali, S. and Harding, B. J. and Riccobono, J. and Migliozzi, M. A. and Souza, J. R. and Mesquita, R. and Dandenault, P. and Wu, Q. and Pimenta, A. A. and Peres, L. and Silva, R.},
  title = {Spectral Contamination of the 6300 Å Emission in Single‐Etalon Fabry‐Perot Interferometers},
  journal = {Journal of Geophysical Research: Space Physics},
  year = {2023},
  volume = {128},
  number = {9},
  doi = {10.1029/2023ja031601}
}
Kostenlos starten →