Large-bore rotational thrombectomy and balloon angioplasty for thrombus fragmentation and removal from occluded iliofemoral or inferior vena cava stents
Vasa · 2025
DOI: 10.1024/0301-1526/a001176 ↗Kurz gefasst
Fachartikel in der Zeitschrift Vasa, 2025. Verfasst von Gabor Forgo und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Angiology, University Hospital Zurich, Switzerland. Hauptthemen laut MEDLINE: Stents, Thrombectomy, Vena Cava, Inferior, Venous Thrombosis. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 18 Literaturangaben.
Abstract (Originalsprache)
Background
Although venous stent placement is an established treatment for patients with deep vein thrombosis (DVT) and post-thrombotic syndrome (PTS), stent patency rate may be as low as 80% at 12 months. Treatment of stent occlusion requires the removal of a large amount of fresh or organized thrombus from stents with a diameter of 12–20 mm. The feasibility of large-bore rotational thrombectomy in combination with angioplasty to treat thrombosed venous iliofemoral or inferior vena cava stents has not been investigated yet. Patients and methods: Between May 2023 and June 2024, 12 patients (15 limbs) with symptomatic venous stent occlusions were treated at our institution with the 10-French Rotarex™ thrombectomy device and completed 3-month follow-up by Duplex ultrasound. The primary outcome was primary patency at 90 days after thrombectomy of stent occlusion. Safety outcomes included device-related complications, bleeding, and death.
Results
Median age was 41 years, 75% were women. At the index procedure, 10 (83%) patients presented with PTS and two (17%) with acute DVT. Median time from index procedure to re-intervention was 1125 (Q1–Q3: 897–2297) days and from symptom onset to re-intervention 39 (Q1–Q3: 8–186) days. Technical success of re-intervention was achieved in all cases, and bail-out stent-in-stent placement was not required in 5 (33%) limbs. The primary patency rate at 90 days was 86.7% (95% CI: 71.0–100.0). Two (17%) patients experienced recurrent stent thrombosis and were managed conservatively. Peri-interventional minor bleeding occurred in two (17%) patients. There were no device-related complications, major bleeding, or deaths.
Conclusions
Large-bore rotational thrombectomy appears to be a feasible strategy to treat iliofemoral and inferior vena cava stent thrombosis, achieving acceptable short-term patency without major adverse events.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Angiology, University Hospital Zurich, Switzerland.
- Department of Biomedical Sciences, Humanitas University, Pieve Emanuele, Italy.
- Centre for Thrombosis and Hemostasis, University Medical Centre Mainz, Germany.
ORCID-Profile: Gabor Forgo, Riccardo Fumagalli, Silvia Cardi, Stefano Barco, Tim Sebastian
Zitieren
APA
Forgo, G., Fumagalli, R., Cardi, S., Barco, S., Kucher, N., & Sebastian, T. (2025). Large-bore rotational thrombectomy and balloon angioplasty for thrombus fragmentation and removal from occluded iliofemoral or inferior vena cava stents. Vasa. https://doi.org/10.1024/0301-1526/a001176
Vancouver
Forgo G, Fumagalli R, Cardi S, Barco S, Kucher N, Sebastian T. Large-bore rotational thrombectomy and balloon angioplasty for thrombus fragmentation and removal from occluded iliofemoral or inferior vena cava stents. Vasa. 2025. doi:10.1024/0301-1526/a001176
BibTeX
@article{Forgo2025,
author = {Forgo, Gabor and Fumagalli, Riccardo and Cardi, Silvia and Barco, Stefano and Kucher, Nils and Sebastian, Tim},
title = {Large-bore rotational thrombectomy and balloon angioplasty for thrombus fragmentation and removal from occluded iliofemoral or inferior vena cava stents},
journal = {Vasa},
year = {2025},
doi = {10.1024/0301-1526/a001176}
}