EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Assessment of Sub-50 nm Nanopipette Emitters for Native Electrospray Ionization Mass Spectrometry

Emily J. Byrd, Eileen J. Olivares, Zoe J. Heidersbach, Raya Sadighi, Khaled Madhoun, Iris Baffour Ansah, Matthew J. Kensil, Luchen Wuyang, Rafael D. Melani, Paolo Actis, Rachel R. Ogorzalek Loo, Frank Sobott und 5 weitere

Journal of the American Society for Mass Spectrometry · 02.11.2026

DOI: 10.1021/jasms.6c00368 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of the American Society for Mass Spectrometry, online erschienen am 02.11.2026. Verfasst von Emily J. Byrd und 16 weiteren Autor:innen. Die Arbeit nennt 73 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Royal Society, Medical Research Council, National Institute of Allergy and Infectious Diseases.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Native mass spectrometry (nMS) is well established for measuring protein masses and stoichiometries using nanoelectrospray ionization (nESI), yet salt adduction and source activation energies can limit routine measurements. In this study, we benchmark submicron quartz nanopipette nESI emitters (<50 nm internal diameter) across four mass spectrometry platforms (quadrupole-time-of-flight, quadrupole-Orbitrap, tribrid-Orbitrap platforms and timsTOF) and a wide protein range (14.5–800 kDa). We analyzed the intrinsically disordered protein alpha synuclein (αS; 14.5 kDa) and holo-myoglobin (17 kDa) with myoglobin further characterized over a range of concentrations (10 μM-1 nM) and capillary voltages to determine concentration ranges and define a gentle operating regime. We additionally observed reduced Na+ adduction and preservation of the Zn2+-bound metalloproteoform of carbonic anhydrase II (29 kDa). Proteins and protein complexes spanning the mid-to-high mass range including ovalbumin (∼44 kDa), malate dehydrogenase (∼70 kDa), transferrin (80 kDa), glutamate dehydrogenase (∼350 kDa), β-galactosidase (∼465 kDa), and GroEL (∼800 kDa) were readily detected using nanopipette emitters. Compared with conventional 1–2 μm internal diameter borosilicate emitters, quartz nanopipettes provided higher signal-to-noise ratios and fewer adducts. Finally, direct analysis of a clarified bacterial lysate expressing αS yielded a clear monomeric charge-state distribution, demonstrating compatibility with complex biological matrices. Collectively, these results establish quartz nanopipette nESI as an instrument-portable, salt-tolerant approach suitable for routine nMS analysis across a broad range of protein molecular weights and sample complexities.

Förderung

  • Royal Society
  • Medical Research Council
  • National Institute of Allergy and Infectious Diseases
  • Wellcome Trust
  • HORIZON EUROPE Marie Sklodowska-Curie Actions
  • National Institute of General Medical Sciences
  • Biotechnology and Biological Sciences Research Council
  • Nederlandse Organisatie voor Wetenschappelijk Onderzoek

Zitieren

APA

Byrd, E. J., Olivares, E. J., Heidersbach, Z. J., Sadighi, R., Madhoun, K., Ansah, I. B., Kensil, M. J., Wuyang, L., Melani, R. D., Actis, P., Loo, R. R. O., Sobott, F., Freedman, K., Su, P., Rijs, A. M., Calabrese, A. N., & Loo, J. A. (2026). Assessment of Sub-50 nm Nanopipette Emitters for Native Electrospray Ionization Mass Spectrometry. Journal of the American Society for Mass Spectrometry. https://doi.org/10.1021/jasms.6c00368

Vancouver

Byrd EJ, Olivares EJ, Heidersbach ZJ, Sadighi R, Madhoun K, Ansah IB, et al. Assessment of Sub-50 nm Nanopipette Emitters for Native Electrospray Ionization Mass Spectrometry. Journal of the American Society for Mass Spectrometry. 2026. doi:10.1021/jasms.6c00368

BibTeX
@article{Byrd2026,
  author = {Byrd, Emily J. and Olivares, Eileen J. and Heidersbach, Zoe J. and Sadighi, Raya and Madhoun, Khaled and Ansah, Iris Baffour and Kensil, Matthew J. and Wuyang, Luchen and Melani, Rafael D. and Actis, Paolo and Loo, Rachel R. Ogorzalek and Sobott, Frank and Freedman, Kevin and Su, Pei and Rijs, Anouk M. and Calabrese, Antonio N. and Loo, Joseph A.},
  title = {Assessment of Sub-50 nm Nanopipette Emitters for Native Electrospray Ionization Mass Spectrometry},
  journal = {Journal of the American Society for Mass Spectrometry},
  year = {2026},
  doi = {10.1021/jasms.6c00368}
}
Kostenlos starten →