EUVIMEDEUVIMED entdecken
Crossref

Isotope-Coded Derivatization Enables Accurate LC–MS/MS Quantification of Urinary THC–COOH without Isotope-Labeled Cannabinoid Standards

Maiko Kusano iD, Shimba Kawasue iD, Yu-Ki Sakamoto, Mahiro Yoshida, Taka-Aki Matsuyama

Journal of the American Society for Mass Spectrometry · 05.08.2026 · 37 (8) · 1840-1847

DOI: 10.1021/jasms.6c00110 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of the American Society for Mass Spectrometry, online erschienen am 24.06.2026. Verfasst von Maiko Kusano und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Legal Medicine, Showa Medical University, 1-5-8 Hatanodai, Shinagawa, Tokyo142-8555, Japan. Hauptthemen laut MEDLINE: Tandem Mass Spectrometry, Dronabinol, Liquid Chromatography-Mass Spectrometry. Die Arbeit nennt 16 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Quantitative determination of 11-nor-9-carboxy-Δ9-tetrahydrocannabinol (THC–COOH) in urine is the internationally accepted approach for verifying cannabis use in forensic toxicology. Accurate liquid chromatography–tandem mass spectrometry (LC–MS/MS) analysis typically relies on stable isotope-labeled internal standards; however, isotope-labeled cannabinoid reference materials are costly, tightly regulated, and not uniformly accessible across laboratories. We report an isotope-coded derivatization (ICD) strategy that enables isotope-dilution–equivalent quantification of urinary THC–COOH without reliance on commercially available isotope-labeled cannabinoid standards. THC–COOH was derivatized with isopropyl-piperidine carboxylic acid hydrazide (IPPAH) and its deuterated analogue (IPPAH-d6), generating a chemically matched analyte/internal standard pair through parallel derivatization. The derivatives exhibited stable chromatographic coelution and closely matched ionization behavior under positive electrospray ionization. Quantitative LC–MS/MS analysis demonstrated linearity over 1–500 ng/mL (r2 > 0.999), with intra- and interday accuracy of 81.8–108.6% and precision below 10%. Internal standard–normalized matrix factors ranged from 97–109% with minimal variability, indicating effective compensation for matrix effects. This compensation enabled reliable quantification without extensive sample cleanup, allowing a simplified sample preparation workflow compared with conventional methods. Derivatized samples remained stable for at least 72 h in the autosampler without detectable isotopic exchange. This ICD strategy provides a quantitatively reliable alternative to conventional isotope dilution while eliminating dependence on isotope-labeled cannabinoid standards, thereby expanding the accessibility of high-confidence LC–MS/MS quantification and illustrating the broader potential of isotope-coded derivatization in forensic mass spectrometry.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tandem Mass SpectrometryDronabinolLiquid Chromatography-Mass SpectrometryHumansIsotope LabelingReproducibility of ResultsLimit of DetectionDeuteriumCannabinoids

Stichwörter der Autor:innen

11-nor-9-carboxy-Δ9-tetrahydrocannabinol (THC−COOH)isotope-coded derivatizationliquid chromatography-tandem mass spectrometryΔ9-tetrahydrocannabinol (Δ9-THC)

Substanzen

Dronabinol11-nor-delta(9)-tetrahydrocannabinol-9-carboxylic acidDeuteriumCannabinoids

Autor:innen und Institutionen

  • Department of Legal Medicine, Showa Medical University, 1-5-8 Hatanodai, Shinagawa, Tokyo142-8555, Japan.
  • National Institute of Health Sciences, 3-25-26 Tonomachi, Kawasaki-ku, Kawasaki, Kanagawa210-9501, Japan.
  • Shimadzu Corporation , 1 Nishinokyo Kuwabara-cho, Nakagyo-ku, Kyoto604-8511, Japan.

ORCID-Profile: Maiko Kusano, Shimba Kawasue

Zitieren

APA

Kusano, M., Kawasue, S., Sakamoto, Y. K., Yoshida, M., & Matsuyama, T. A. (2026). Isotope-Coded Derivatization Enables Accurate LC–MS/MS Quantification of Urinary THC–COOH without Isotope-Labeled Cannabinoid Standards. Journal of the American Society for Mass Spectrometry, 37(8), 1840-1847. https://doi.org/10.1021/jasms.6c00110

Vancouver

Kusano M, Kawasue S, Sakamoto YK, Yoshida M, Matsuyama TA. Isotope-Coded Derivatization Enables Accurate LC–MS/MS Quantification of Urinary THC–COOH without Isotope-Labeled Cannabinoid Standards. Journal of the American Society for Mass Spectrometry. 2026;37(8):1840-1847. doi:10.1021/jasms.6c00110

BibTeX
@article{Kusano2026,
  author = {Kusano, Maiko and Kawasue, Shimba and Sakamoto, Yu-Ki and Yoshida, Mahiro and Matsuyama, Taka-Aki},
  title = {Isotope-Coded Derivatization Enables Accurate LC–MS/MS Quantification of Urinary THC–COOH without Isotope-Labeled Cannabinoid Standards},
  journal = {Journal of the American Society for Mass Spectrometry},
  year = {2026},
  volume = {37},
  number = {8},
  pages = {1840--1847},
  doi = {10.1021/jasms.6c00110}
}
Kostenlos starten →