Control of Antibody Orientation on Graphene Using Porphyrin Linker Molecules for High-Performance Graphene-Based Immuno-Biosensors
Journal of the American Chemical Society · 24.12.2025 · 147 (51) · 47638-47653
DOI: 10.1021/jacs.5c17186 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of the American Chemical Society, online erschienen am 09.12.2025. Verfasst von Tianyi Yin und 16 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Complex, Severe, and Rare Diseases, Biomedical Engineering Facility of National Infrastructures for Translational Medicine, P…. Hauptthemen laut MEDLINE: Graphite, Porphyrins, Biosensing Techniques, Antibodies. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 82 Literaturangaben. Gefördert von: Engineering and Physical Sciences Research Council, National Key Research and Development Program of China, Wellcome Trust.
Abstract (Originalsprache)
The appropriate orientation of antibodies on the graphene surface is critical for the high performance of graphene biosensors. In this article, we show that a predominantly vertical orientation of antibodies to the graphene surface can be achieved by functionalizing the surface with tetrakis (4-carboxyphenyl) porphyrin (TCPP). Unlike conventional pyrene-based linkers, such as 1-pyrene butanoic acid succinimidyl ester (PBASE), which rely on a single flexible chain, the rigid porphyrin macrocycle of TCPP forms an extended π-π network with graphene and provides sites for uniform and directional antibody coupling. Applying this system to a graphene field effect transistor platform for exosome detection, we achieved 2 orders of magnitude improvement in the detection limit compared to PBASE-functionalized sensors. Computational and experimental analysis revealed that the antibody can highly exhibit vertical orientation on TCPP-functionalized graphene, while mixed orientations on PBASE-functionalized graphene confirm that the sensitivity enhancement is directly caused by the optimized orientation. The high efficiency of the TCPP method was further validated by successfully detecting pancreatic cancer exosome biomarkers in clinical samples. This biofunctionalization method could enable ultrasensitive detection of disease biomarkers on a graphene surface.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- State Key Laboratory of Complex, Severe, and Rare Diseases, Biomedical Engineering Facility of National Infrastructures for Translational Medicine, Peking Union Medical College Hospital, Chinese Academy of Medical Scien…
- Department of Materials, Imperial College London, Exhibition Road, London SW7 2AZ, U.K.
- Department of Computing, Imperial College London, Exhibition Road, London SW7 2AZ, U.K.
- Hamlyn Centre, Imperial College London, Exhibition Road, London SW7 2AZ, U.K.
- Facility for Imaging by Light Microscopy, Imperial College London, Exhibition Road, London SW7 2AZ, U.K.
- Oncology Section, Surrey Cancer Research Institute, Department of Clinical and Experimental Medicine, FHMS, University of Surrey, The Leggett Building, Daphne Jackson Road, Guildford GU2 7WG, U.K.
ORCID-Profile: Tianyi Yin, David C A Gaboriau, Meysam Keshavarz, Ahmad Nizamuddin Bin Muhammad Mustafa, Peter K Petrov, Stephen J Skinner, Yi Hu, Sami Ramadan
Förderung
- Engineering and Physical Sciences Research Council
- National Key Research and Development Program of China
- Wellcome Trust
- Biotechnology and Biological Sciences Research Council
- Cancer Research UK
- National High Level Hospital Clinical Research Funding
Zitieren
APA
Yin, T., Xu, X., Huang, Z., Rosa, B. G., Gaboriau, D. C. A., Merali, N., Keshavarz, M., Bin Muhammad Mustafa, A. N., Song, J., Alodan, S., Petrov, P. K., Frampton, A. E., Skinner, S. J., Alford, N., Hu, Y., Ramadan, S., & Klein, N. (2025). Control of Antibody Orientation on Graphene Using Porphyrin Linker Molecules for High-Performance Graphene-Based Immuno-Biosensors. Journal of the American Chemical Society, 147(51), 47638-47653. https://doi.org/10.1021/jacs.5c17186
Vancouver
Yin T, Xu X, Huang Z, Rosa BG, Gaboriau DCA, Merali N, et al. Control of Antibody Orientation on Graphene Using Porphyrin Linker Molecules for High-Performance Graphene-Based Immuno-Biosensors. Journal of the American Chemical Society. 2025;147(51):47638-47653. doi:10.1021/jacs.5c17186
BibTeX
@article{Yin2025,
author = {Yin, Tianyi and Xu, Xi and Huang, Zhiping and Rosa, Bruno Gil and Gaboriau, David C A and Merali, Nabeel and Keshavarz, Meysam and Bin Muhammad Mustafa, Ahmad Nizamuddin and Song, Jiapeng and Alodan, Sarah and Petrov, Peter K and Frampton, Adam E and Skinner, Stephen J and Alford, Neil and Hu, Yi and Ramadan, Sami and Klein, Norbert},
title = {Control of Antibody Orientation on Graphene Using Porphyrin Linker Molecules for High-Performance Graphene-Based Immuno-Biosensors},
journal = {Journal of the American Chemical Society},
year = {2025},
volume = {147},
number = {51},
pages = {47638--47653},
doi = {10.1021/jacs.5c17186}
}
EUVIMED