Portable Photoactivated Room-Temperature Gas Sensor for On-Site Methanol Monitoring

Haoshuang Zhang, Tianshuang Wang iD, Guoxuan Gu, Xueying Kou, Yongshun Liu, Peng Sun iD, Geyu Lu

ACS Sensors · 10.11.2026

DOI: 10.1021/acssensors.6c03752 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS Sensors, online erschienen am 10.11.2026. Verfasst von Haoshuang Zhang und 6 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Integrated Optoelectronics, College of Electronic Science and Engineering, College of Integrated Circuits, Jilin University, …. Die Arbeit nennt 64 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Department of Science and Technology of Jilin Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Methanol is an essential chemical feedstock and renewable fuel, yet its high volatility and flammability necessitate intrinsically safe room-temperature detection for safe deployment. Current room-temperature methanol sensing technologies, however, suffer from inadequate sensitivity and high detection limits, hindering reliable early leakage warning. Herein, we report a photoactivated room-temperature, chemiresistive methanol sensor based on bimetallic PdPt clusters-decorated W18O49. Bimetallic PdPt clusters with tunable compositions dramatically improve the sensor receptor function via selectively increasing the adsorption of chemisorbed oxygen species and methanol molecules, as revealed by theoretical calculations. Meanwhile, ultraviolet (UV) photoactivation replaces thermal activation by promoting charge-carrier generation and surface redox reactions, while the Schottky barrier enables efficient charge-carrier separation, thereby enhancing the sensor transducer function. The enhanced sensing reaction pathway is elucidated by in situ diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS) under UV irradiation. Accordingly, the sensor exhibits a more than fourfold enhancement in response, low detection limit (100 ppb), and stable operation for over 30 days in ambient air at room temperature. Finally, we integrate the sensor into a portable on-site monitoring device, providing an intrinsically safe platform for real-time methanol leakage monitoring and early warning in hazardous industrial environments.

Schlagwörter

Stichwörter der Autor:innen

bimetallic PdPt clustersmethanolon-site detectionphotoactivated chemiresistive sensorroom temperature

Autor:innen und Institutionen

  • State Key Laboratory of Integrated Optoelectronics, College of Electronic Science and Engineering, College of Integrated Circuits, Jilin University, Changchun, China.
  • International Center of Future Science, Jilin University, Changchun, China.
  • School of Electronic and Information Engineering, Changchun University of Science and Technology, Changchun, China.

ORCID-Profile: Tianshuang Wang, Peng Sun

Förderung

  • National Natural Science Foundation of China
  • Department of Science and Technology of Jilin Province

Zitieren

APA

Zhang, H., Wang, T., Gu, G., Kou, X., Liu, Y., Sun, P., & Lu, G. (2026). Portable Photoactivated Room-Temperature Gas Sensor for On-Site Methanol Monitoring. ACS Sensors. https://doi.org/10.1021/acssensors.6c03752

Vancouver

Zhang H, Wang T, Gu G, Kou X, Liu Y, Sun P, et al. Portable Photoactivated Room-Temperature Gas Sensor for On-Site Methanol Monitoring. ACS Sensors. 2026. doi:10.1021/acssensors.6c03752

BibTeX
@article{Zhang2026,
  author = {Zhang, Haoshuang and Wang, Tianshuang and Gu, Guoxuan and Kou, Xueying and Liu, Yongshun and Sun, Peng and Lu, Geyu},
  title = {Portable Photoactivated Room-Temperature Gas Sensor for On-Site Methanol Monitoring},
  journal = {ACS Sensors},
  year = {2026},
  doi = {10.1021/acssensors.6c03752}
}
Kostenlos starten →