EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Architecture-Dependent Effects of Terminal Switching of Thiol Anchors and Methylene Blue Reporters in Electrochemical DNA-Based Sensors

Qiuyue Yang, Maria Cambra-Pellejà, Javiera Burgos-Avila, Amadeo Sena, Alejandro Chamorro-Garcia, Andrea Idili, Miguel Vilaplana, Daniel Camprubí-Ferrer, Jose Muñoz, Javier Gandasegui, Claudio Parolo

ACS Sensors · 18.11.2026

DOI: 10.1021/acssensors.6c03138 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS Sensors, online erschienen am 18.11.2026. Verfasst von Qiuyue Yang und 10 weiteren Autor:innen. Die Arbeit nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: 'la Caixa' Foundation, H2020 Marie Sklodowska-Curie Actions, Ministerio de Ciencia, Tecnolog?a e Innovaci?n.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The terminal placement of surface anchors and redox reporters is a fundamental but often under-optimized design parameter in electrochemical DNA-based sensors. Most architectures use a 5’ thiol anchor and a 3’ methylene blue reporter by convention, although switching these terminal modifications can alter probe orientation, target accessibility, reporter behavior, and signal transduction. Here, we systematically investigated the effect of switching thiol anchors and methylene blue reporters across three electrochemical DNA-based sensor architectures: an electrochemical DNA sensor for complementary DNA detection, an electrochemical aptamer-based sensor for Plasmodium falciparum lactate dehydrogenase detection, and an E-DNA scaffold sensor for antibody detection. Terminal switching produced architecture-dependent effects. In asymmetric electrochemical DNA sensors, switching increased signal gain and produced a lower apparent dissociation constant under matched-frequency interrogation (24.1 vs 7.8 nM for ORI and SWI, respectively). In the aptamer-based sensor, switching generated a low-frequency signal-ON response and improved signal gain at selected interrogation frequencies. By contrast, in the E-DNA scaffold sensor, the original orientation outperformed the switched architecture, producing a higher signal change, improved signal-to-background ratio, and faster apparent response kinetics. These results demonstrate that terminal modification placement is not a neutral synthetic choice but a determinant of signal transduction and analytical performance. More broadly, this work establishes terminal switching as a simple design variable for tuning electrochemical DNA, aptamer-based, and scaffold-based sensors through deliberate optimization of terminal architecture.

Förderung

  • 'la Caixa' Foundation
  • H2020 Marie Sklodowska-Curie Actions
  • Ministerio de Ciencia, Tecnolog?a e Innovaci?n
  • Ministero dell'Universit? e della Ricerca
  • NextGenerationEU
  • Generalitat de Catalunya
  • Instituto de Salud Carlos III
  • Hospital Cl?nic de Barcelona

Zitieren

APA

Yang, Q., Cambra-Pellejà, M., Burgos-Avila, J., Sena, A., Chamorro-Garcia, A., Idili, A., Vilaplana, M., Camprubí-Ferrer, D., Muñoz, J., Gandasegui, J., & Parolo, C. (2026). Architecture-Dependent Effects of Terminal Switching of Thiol Anchors and Methylene Blue Reporters in Electrochemical DNA-Based Sensors. ACS Sensors. https://doi.org/10.1021/acssensors.6c03138

Vancouver

Yang Q, Cambra-Pellejà M, Burgos-Avila J, Sena A, Chamorro-Garcia A, Idili A, et al. Architecture-Dependent Effects of Terminal Switching of Thiol Anchors and Methylene Blue Reporters in Electrochemical DNA-Based Sensors. ACS Sensors. 2026. doi:10.1021/acssensors.6c03138

BibTeX
@article{Yang2026,
  author = {Yang, Qiuyue and Cambra-Pellejà, Maria and Burgos-Avila, Javiera and Sena, Amadeo and Chamorro-Garcia, Alejandro and Idili, Andrea and Vilaplana, Miguel and Camprubí-Ferrer, Daniel and Muñoz, Jose and Gandasegui, Javier and Parolo, Claudio},
  title = {Architecture-Dependent Effects of Terminal Switching of Thiol Anchors and Methylene Blue Reporters in Electrochemical DNA-Based Sensors},
  journal = {ACS Sensors},
  year = {2026},
  doi = {10.1021/acssensors.6c03138}
}
Kostenlos starten →