Implantable Graphene Fiber Sensor Functionalized with Enzyme-Mimicking Fe-Porphyrin for In Vivo Simultaneous Monitoring of NO and H2O2 in Cancer
ACS Sensors · 2026
DOI: 10.1021/acssensors.6c02929 ↗Kurz gefasst
Fachartikel in der Zeitschrift ACS Sensors, 2026. Verfasst von Shanting Li und 8 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Material Chemistry for Energy Conversion and Storage, Ministry of Education, School of Chemistry and Chemical Engineering, Huazhong…. Hauptthemen laut MEDLINE: Hydrogen Peroxide, Graphite, Biosensing Techniques, Nitric Oxide. Die Arbeit nennt 58 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Foundation of Daye Lake Future Industry (Hydrogen Energy) Joint Laboratory.
Abstract (Originalsprache)
Nitric oxide (NO) and hydrogen peroxide (H2O2) are critical in redox homeostasis, cell signaling, and tumor progression, yet the simultaneous detection of both remains challenging due to their low concentrations and high reactivity. Herein, we developed an implantable, fully flexible electrochemical biosensor based on a Fe-porphyrin metal–organic framework (i.e., PCN-224(Fe)) for real-time monitoring of NO and H2O2 in complex biological environments. This platform employs PCN-224(Fe) with enzyme-mimicking activity as the catalytic material, combined with nitrogen and boron codoped graphene fiber as the freestanding and flexible microelectrode substrate. The resultant electrochemical sensor demonstrated outstanding performance, with detection limits of 3.0 nM for NO and 0.5 μM for H2O2, and sensitivities of 2.99 mA cm–2 mM–1 and 1.04 mA cm–2 mM–1, respectively. This performance surpasses most previously reported electrochemical sensors. The sensor also shows excellent selectivity and reproducibility, facilitating continuous monitoring of NO and H2O2 signals in the tumor microenvironment. The proposed fiber-based sensor enables in situ, real-time, continuous monitoring of NO and H2O2 in cancer cells, tissues, and living organisms, thereby effectively discriminating between cancerous and normal samples based on significantly elevated biomarker levels in malignant tissues. When implanted directly into living tissues, the sensing device captures dynamic biomarker fluctuations in vivo with high fidelity, offering a distinct advantage over traditional in vitro assays, which often introduce signal loss and concentration artifacts during sample processing. As a result, this approach provides a more accurate reflection of actual in vivo conditions and holds great promise for assessing tumor progression as well as monitoring therapeutic responses.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Key Laboratory of Material Chemistry for Energy Conversion and Storage, Ministry of Education, School of Chemistry and Chemical Engineering, Huazhong University of Science & Technology, Wuhan430074, China.
- Key Laboratory of Microbiome and Esophageal Cancer Prevention and Treatment, The First Affiliated Hospital, College of Clinical Medicine, Henan University of Science and Technology, Luoyang471003, China.
ORCID-Profile: Fei Xiao
Förderung
- National Natural Science Foundation of China
- Foundation of Daye Lake Future Industry (Hydrogen Energy) Joint Laboratory
Zitieren
APA
Li, S., Yao, K., Hu, M., Huang, W., Wang, D., Zhang, H., Chang, T., Xiao, F., & Zhao, A. (2026). Implantable Graphene Fiber Sensor Functionalized with Enzyme-Mimicking Fe-Porphyrin for In Vivo Simultaneous Monitoring of NO and H2O2 in Cancer. ACS Sensors. https://doi.org/10.1021/acssensors.6c02929
Vancouver
Li S, Yao K, Hu M, Huang W, Wang D, Zhang H, et al. Implantable Graphene Fiber Sensor Functionalized with Enzyme-Mimicking Fe-Porphyrin for In Vivo Simultaneous Monitoring of NO and H2O2 in Cancer. ACS Sensors. 2026. doi:10.1021/acssensors.6c02929
BibTeX
@article{Li2026,
author = {Li, Shanting and Yao, Kaiyuan and Hu, Min and Huang, Wei and Wang, Dan and Zhang, Hengrui and Chang, Tengyun and Xiao, Fei and Zhao, Anshun},
title = {Implantable Graphene Fiber Sensor Functionalized with Enzyme-Mimicking Fe-Porphyrin for In Vivo Simultaneous Monitoring of NO and H2O2 in Cancer},
journal = {ACS Sensors},
year = {2026},
doi = {10.1021/acssensors.6c02929}
}
EUVIMED