From Sensor Design to Force Maps: A Systematic Evaluation of Förster Resonance Energy Transfer-Based Tension Probes
ACS Sensors · 19.11.2026
DOI: 10.1021/acssensors.6c02594 ↗Kurz gefasst
Fachartikel in der Zeitschrift ACS Sensors, online erschienen am 19.11.2026. Verfasst von Samet Aytekin und 6 weiteren Autor:innen. Die Arbeit nennt 43 Literaturangaben. Gefördert von: KU Leuven, Fonds Wetenschappelijk Onderzoek, Onderzoeksraad, KU Leuven.
Abstract (Originalsprache)
Mechanical forces transmitted through focal adhesions regulate cell behavior and disease progression, yet remain difficult to quantify at the molecular level. Genetically encoded FRET-based tension probes enable measurements of piconewton-scale forces across specific proteins in living cells, but their quantitative interpretation is highly sensitive to probe design and measurement modality. Here, we systematically compared vinculin tension sensors under identical experimental conditions, evaluating unloaded reference constructs, fluorophore pairs, mechanical sensor modules, and circularly permuted variants. Unloaded controls established a common no-force baseline and validated force-dependent readout. Among the fluorophore pairs tested, the green-red combination Clover-mScarlet-I yielded a higher unloaded FRET efficiency and hence a broader measurable dynamic range. Comparison of six mechanical sensor modules showed that the binary-response sensors FL and CC-S2 produced the largest force-dependent FRET changes and the steepest proximal-to-distal tension gradient. Circular permutation experiments revealed that fluorophore orientation has a strong, module-dependent influence on the measured FRET readout. Together, these results establish a comparative framework for interpreting FLIM-based vinculin tension measurements and provide practical design principles for selecting and engineering molecular tension probes.
Förderung
- KU Leuven
- Fonds Wetenschappelijk Onderzoek
- Onderzoeksraad, KU Leuven
Zitieren
APA
Aytekin, S., Vorsselmans, S., Vankevelaer, G., Poedts, B., Hofkens, J., Hendrix, J., & Rocha, S. (2026). From Sensor Design to Force Maps: A Systematic Evaluation of Förster Resonance Energy Transfer-Based Tension Probes. ACS Sensors. https://doi.org/10.1021/acssensors.6c02594
Vancouver
Aytekin S, Vorsselmans S, Vankevelaer G, Poedts B, Hofkens J, Hendrix J, et al. From Sensor Design to Force Maps: A Systematic Evaluation of Förster Resonance Energy Transfer-Based Tension Probes. ACS Sensors. 2026. doi:10.1021/acssensors.6c02594
BibTeX
@article{Aytekin2026,
author = {Aytekin, Samet and Vorsselmans, Sarah and Vankevelaer, Giel and Poedts, Bert and Hofkens, Johan and Hendrix, Jelle and Rocha, Susana},
title = {From Sensor Design to Force Maps: A Systematic Evaluation of Förster Resonance Energy Transfer-Based Tension Probes},
journal = {ACS Sensors},
year = {2026},
doi = {10.1021/acssensors.6c02594}
}